dc.description.abstract | Ground-supported cylindrical tanks are used to store a variety of liquids. This paper provides
the theoretical background for takes into account impulsive and convective (sloshing) actions of the
fluid in concrete containers fixed to rigid foundations; it has been adopted in Eurocode 8. Seismic
responses – base shears, the bending and overturning moments – are calculated by using the response spectra of the earthquake in Loma Prieta, California (18.10.1989). As the examples is analyzed the ground supported cylindrical concrete tanks, fluid filling is H = 2 m and R are depended from tank slenderness ratio = H/R. For considered tank slenderness ratios = 0.3, 0.5, 0.7, 1, 2, 3 R are given 6.667 m, 4 m, 2.857 m, 2 m, 1 m and 0.667 m. | cs |
dc.format.extent | 244757 bytes | |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | cs |
dc.publisher | Vysoká škola báňská - Technická univerzita Ostrava | cs |
dc.relation.ispartofseries | Sborník vědeckých prací Vysoké školy báňské - Technické univerzity Ostrava. Řada stavební | cs |
dc.rights | © Vysoká škola báňská - Technická univerzita Ostrava | cs |
dc.subject | fluid | cs |
dc.subject | earthquake | cs |
dc.subject | tank | cs |
dc.title | Seismic response of liquid storage ground supported tanks for different slenderness ratio | cs |
dc.type | article | cs |
dc.rights.access | openAccess | |
dc.type.version | publishedVersion | cs |
dc.type.status | Peer-reviewed | cs |