dc.description.abstract | This paper describes the probabilistic nonlinear analysis of the containment hermetic cover of
main shut-off valve (MSV) under an extreme internal overpressure and temperature. The scenario of
the hard accident in NPP and the methodology of the calculation of the fragility curve of the failure
overpressure using the probabilistic safety assessment PSA 2 level are presented. The elasto-plastic
behavior of steel material dependent on temperature was considered in software ANSYS. The method
of central composite design sampling (CCD) of the response surface methodology (RSM) was used
to probability and sensitivity analysis of the hermetic cover reliability. | cs |
dc.format.extent | 701042 bytes | |
dc.format.mimetype | application/pdf | |
dc.language | Neuvedeno | cs |
dc.language.iso | en | cs |
dc.publisher | Vysoká škola báňská - Technická univerzita Ostrava | |
dc.relation.ispartofseries | Sborník vědeckých prací Vysoké školy báňské - Technické univerzity Ostrava. Řada stavební | |
dc.relation.uri | https://www.degruyter.com/downloadpdf/j/tvsb.2017.17.issue-1/tvsb-2017-0012/tvsb-2017-0012.pdf | |
dc.rights | © Vysoká škola báňská - Technická univerzita Ostrava | |
dc.rights | © 2017 Juraj Králik, published by De Gruyter Open. This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. BY-NC-ND 3.0 | |
dc.subject | nuclear power plant | cs |
dc.subject | MSV cover | cs |
dc.subject | nonlinearity | cs |
dc.subject | fragility curve | cs |
dc.subject | PSA | cs |
dc.subject | RSM | cs |
dc.subject | ANSYS | cs |
dc.title | Probability and sensitivity nonlinear analysis of the hermetic cover of main shut-off valve under extreme pressure and temperature | cs |
dc.type | article | cs |
dc.identifier.doi | 10.1515/tvsb-2017-0012 | |
dc.rights.access | openAccess | |