dc.description.abstract | This work is focused on measurement of heart sounds, localization of PCG sensors and analysis
of the acquired signals. Two auscultation sites were designed for the synchronized measurement
of several PCG signals. The automatic multiple source heart sound detector of the first and the
second heart sound was designed as well. The designed detector uses the Shannon energy to
obtain an envelope of a PCG signal and synchronization with the R peak and the T wave of an
electrocardiogram for accurate determination of the heart sounds. The main result of this work
is the analysis of the phonocardiographic signal obtained from different positions on the chest
and the comparison of the differences in the time domain for various auscultation areas. | en |
dc.description.abstract | Tato práce je zaměřená na měření srdečních ozev, umístění senzorů srdečních ozev a následnou
analýzu získaných signálů. V rámci této práce byly navrhnuty dvě auskultační sítě, pro
synchronizované měření několika PCG signálů najednou. Rovněž byl navrhnutý automatický
multikanálový detektor první a druhé srdeční ozvy. Navržený detektor využívá Shannonovy
energie k získání obálky fonokardiografického signálu a následnou synchronizaci s R hrotem a
T vlnou elektrokardiogramu k přesnému určení srdečních ozev. Hlavním výsledkem této práce
je analýza fonokardiografického signálu získaného z jednotlivých míst na hrudníku a porovnání
rozdílů pro různá auskultační místa v časové oblasti. | cs |
dc.format.extent | 5956952 bytes | |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | |
dc.publisher | Vysoká škola báňská - Technická univerzita Ostrava | cs |
dc.subject | Phonocardiography | en |
dc.subject | PCG | en |
dc.subject | Auscultation | en |
dc.subject | Auscultation site | en |
dc.subject | Localisation | en |
dc.subject | Signal
Processing | en |
dc.subject | Fonokardiokrafie | cs |
dc.subject | PCG | cs |
dc.subject | Auskultace | cs |
dc.subject | Auskultační síť | cs |
dc.subject | Lokalizace | cs |
dc.subject | Zpracování
signálu | cs |
dc.title | Optimum Localization of Phonocardiographic Sensors and Analysis of These Signals | en |
dc.title.alternative | Optimaliazce umístění fonokardiografického senzoru a analýza měřených signálů | cs |
dc.type | Diplomová práce | cs |
dc.contributor.referee | Fontecave-Jallon, Julie | |
dc.date.accepted | 2019-05-30 | |
dc.thesis.degree-name | Ing. | |
dc.thesis.degree-level | Magisterský studijní program | cs |
dc.thesis.degree-grantor | Vysoká škola báňská - Technická univerzita Ostrava. Fakulta elektrotechniky a informatiky | cs |
dc.description.department | 450 - Katedra kybernetiky a biomedicínského inženýrství | cs |
dc.thesis.degree-program | Elektrotechnika | cs |
dc.thesis.degree-branch | Biomedicínské inženýrství | cs |
dc.description.result | výborně | cs |
dc.identifier.sender | S2724 | |
dc.identifier.thesis | FOJ0066_FEI_N2649_3901T009_2019 | |
dc.rights.access | openAccess | |