Show simple item record

dc.contributor.authorBarvík, Daniel
dc.contributor.authorČerný, Martin
dc.contributor.authorPenhaker, Marek
dc.contributor.authorNoury, Norbert
dc.date.accessioned2022-07-08T10:52:05Z
dc.date.available2022-07-08T10:52:05Z
dc.date.issued2022
dc.identifier.citationIEEE Reviews in Biomedical Engineering. 2022, vol. 15, p. 138-151.cs
dc.identifier.issn1937-3333
dc.identifier.issn1941-1189
dc.identifier.urihttp://hdl.handle.net/10084/146347
dc.description.abstractNoninvasive continuous blood pressure estimation is a promising alternative to minimally invasive blood pressure measurement using cuff and invasive catheter measurement, because it opens the way to both long-term and continuous blood pressure monitoring in ecological situation. The most current estimation algorithm is based on pulse transit time measurement where at least two measured signals need to be acquired. From the pulse transit time values, it is possible to estimate the continuous blood pressure for each cardiac cycle. This measurement highly depends on arterial properties which are not easily accessible with common measurement techniques; but these properties are needed as input for the estimation algorithm. With every change of input arterial properties, the error in the blood pressure estimation rises, thus a periodic calibration procedure is needed for error minimization. Recent research is focused on simplified constant arterial properties which are not constant over time and uses only linear model based on initial measurement. The elaboration of continuous calibration procedures, independent of recalibration measurement, is the key to improving the accuracy and robustness of noninvasive continuous blood pressure estimation. However, most models in literature are based on linear approximation and we discuss here the need for more complete calibration models.cs
dc.language.isoencs
dc.publisherIEEEcs
dc.relation.ispartofseriesIEEE Reviews in Biomedical Engineeringcs
dc.relation.urihttps://doi.org/10.1109/RBME.2021.3109643cs
dc.rightsCopyright © 2022, IEEEcs
dc.subjectcalibration procedurecs
dc.subjectnoninvasive continuous blood pressurecs
dc.subjectcuffless blood pressurecs
dc.subjectpulse transit timecs
dc.subjectpulse wave velocitycs
dc.subjectpulse wave analysiscs
dc.subjectphotoplethysmographycs
dc.subjectimpedance plethysmographycs
dc.titleNoninvasive continuous blood pressure estimation from pulse transit time: A review of the calibration modelscs
dc.typearticlecs
dc.identifier.doi10.1109/RBME.2021.3109643
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume15cs
dc.description.lastpage151cs
dc.description.firstpage138cs
dc.identifier.wos000745516700013


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record