dc.identifier.citationEnvironmental Pollution. 2017, vol. 225, p. 31-39.cs
dc.identifier.issn0269-7491
dc.identifier.issn1873-6424
dc.identifier.urihttp://hdl.handle.net/10084/117126
dc.description.abstractFive different domestic heating boilers (automatic, over-fire, with down-draft combustion and gasification) and three types of fuel (lignite, wood and mixed fuel) were examined in 25 combustion tests and correlated with the emissions of particulate matter (PM), carbon monoxide (CO), total organic carbon (TOC) and 12 polycyclic aromatic hydrocarbons (PAHs with MW = 178-278 g/mol) focusing on particle phase. However, the distribution of 12 PAHs in gas phase was considered as well due to the presence mainly of lighter PAHs in gas phase. The PAHs, as well as the CO and TOC, are the indicators of incomplete combustion, and in this study PAH emission increased significantly with increasing emissions of CO and TOC. The PAHs were mainly detected on PM2.5, their contents were increasing linearly with increasing PM2.5 emissions. The highest emission factors of PAHs were measured for boilers of old construction, such as over-fire boiler (5.8-929 mg/kg) and boiler with down-draft combustion (3.1-54.1 mg/kg). Modern types of boilers produced much lower emissions of PAHs, in particular, automatic boiler (0.3-3.3 mg/kg) and gasification boilers (0.2-6.7 mg/kg). In general, the inefficient combustion at reduced output of boilers generated 1.4-17.7 times more emissions of PAHs than the combustion at nominal output of boilers. It is recommended to operate boilers at nominal output with sufficient air supply and to use the proper fuel to minimise PAHs emissions from domestic heating appliances.cs
dc.language.isoencs
dc.publisherElseviercs
dc.relation.ispartofseriesEnvironmental Pollutioncs
dc.relation.urihttps://doi.org/10.1016/j.envpol.2017.03.034cs
dc.rights© 2017 Elsevier Ltd. All rights reserved.cs
dc.subjectdomestic heatingcs
dc.subjecthot water boilercs
dc.subjectparticulate mattercs
dc.subjectPAHscs
dc.subjectbenzo[a]pyrenecs
dc.titlePAH emissions from old and new types of domestic hot water boilerscs
dc.typearticlecs
dc.identifier.doi10.1016/j.envpol.2017.03.034
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume225cs
dc.description.lastpage39cs
dc.description.firstpage31cs
dc.identifier.wos000401679200004