Analysis of locking self-taping bone screws for angularly stable plates
dc.contributor.author | Čada, Radek | |
dc.contributor.author | Frydrýšek, Karel | |
dc.contributor.author | Sejda, František | |
dc.contributor.author | Demel, Jiří | |
dc.contributor.author | Pleva, Leopold | |
dc.date.accessioned | 2017-09-11T11:39:44Z | |
dc.date.available | 2017-09-11T11:39:44Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Journal of Medical and Biological Engineering. 2017, vol. 37, issue 4, p. 612-625. | cs |
dc.identifier.issn | 1609-0985 | |
dc.identifier.issn | 2199-4757 | |
dc.identifier.uri | http://hdl.handle.net/10084/120218 | |
dc.description.abstract | Paper focuses on biomechanics, specifically on locking cortical bone screws in angularly stable plates used for the treatment of bone fractures in the medical fields of traumatology and orthopaedics. During extraction of titanium-alloy implants, problems are encountered in an effort to loosen some locking bone screws from the locking holes of an angularly stable plate and the subsequent stripping of the internal hexagon of the screw head. The self-locking of the screw-plate threaded joint was verified by calculation and the effect of the angle of the thread on the head of the locking cortical bone screw on self-locking was evaluated. The magnitude of the torque, causing the stripping of the internal hexagon (the Inbus type head) of a locking cortical bone screw with a shank diameter of 3.5 mm from Ti6Al4 V titanium alloy to ISO 5832-3, was determined experimentally. Also, it was experimentally found that the rotation of the screwdriver end with a hexagonal tip inside the locking cortical bone screw head during stripping of the internal hexagon causes strain of the screw head perimeter and thereby an increase of thread friction. The effect of tightening torque on the possibility of loosening of the locking cortical bone screw from the locking hole of an angularly stable plate was assessed experimentally. From the evaluation of five alternative shapes of locking cortical bone screw heads in terms of the acting stress and generated strains, it follows that the best screw is the screw with the Torx type head, which demonstrates the lowest values of reduced stress and equivalent plastic strain. Based on experiments and simulations the authors recommend that all global producers of locking cortical bone screws for locking holes of angularly stable plates use the Torx type heads, and not heads of the Inbus type or the Square, PH, PZ types. | cs |
dc.format.extent | 2351329 bytes | |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | cs |
dc.publisher | Springer | cs |
dc.relation.ispartofseries | Journal of Medical and Biological Engineering | cs |
dc.relation.uri | http://dx.doi.org/10.1007/s40846-017-0279-4 | cs |
dc.rights | © The Author(s) 2017. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | cs |
dc.subject | traumatology | cs |
dc.subject | orthopaedics | cs |
dc.subject | locking bone screw | cs |
dc.subject | angularly stable plate | cs |
dc.subject | osteosynthesis | cs |
dc.subject | biomechanics | cs |
dc.title | Analysis of locking self-taping bone screws for angularly stable plates | cs |
dc.type | article | cs |
dc.identifier.doi | 10.1007/s40846-017-0279-4 | |
dc.rights.access | openAccess | |
dc.type.version | publishedVersion | cs |
dc.type.status | Peer-reviewed | cs |
dc.description.source | Web of Science | cs |
dc.description.volume | 37 | cs |
dc.description.issue | 4 | cs |
dc.description.lastpage | 625 | cs |
dc.description.firstpage | 612 | cs |
dc.identifier.wos | 000407949800016 |
Files in this item
This item appears in the following Collection(s)
-
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals [6377]
Články z časopisů (od roku 2008), které v době vydání článku měly impakt faktor. -
Publikační činnost VŠB-TUO ve Web of Science / Publications of VŠB-TUO in Web of Science [7798]
Kolekce obsahuje bibliografické záznamy článků akademických pracovníků VŠB-TUO publikovaných v časopisech indexovaných ve Web of Science od roku 1990 po současnost. -
Publikační činnost Katedry aplikované mechaniky / Publications of Department of Applied Mechanics (330) [126]
Kolekce obsahuje bibliografické záznamy publikační činnosti (článků) akademických pracovníků Katedry aplikované mechaniky (330) v časopisech registrovaných ve Web of Science od roku 2003 po současnost. -
Publikační činnost Katedry mechanické technologie / Publications of Department of Mechanical Technology (345) [107]
Kolekce obsahuje bibliografické záznamy publikační činnosti (článků) akademických pracovníků Katedry mechanické technologie (345) v časopisech registrovaných ve Web of Science od roku 2003 po současnost. -
OpenAIRE [5085]
Kolekce určená pro sklízení infrastrukturou OpenAIRE; obsahuje otevřeně přístupné publikace, případně další publikace, které jsou výsledkem projektů rámcových programů Evropské komise (7. RP, H2020, Horizon Europe).
Except where otherwise noted, this item's license is described as © The Author(s) 2017. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.