dc.description.abstractReliability and security of a power transmission depends on the state of the power grid and mainly on the state of the Extra-High Voltage pylons. The paper deals with deformation analysis of existing steel structure of selected Extra-High Voltage pylons which showed excessive differences comparing to the original design. In the assessment of the situation, geodetic survey of selected pylons of power grid that showed the greatest deformation was performed. On taken images, deformation of steel structures by using the FOTOMNG system was also analyzed. The proposed method allows a modeling of the structure of the object based on precisely obtained photographic documentation of the current state. It also represents a very effective method which allows to quickly and efficiently analyze the deformation in the structure of Extra-High Voltage pylons in the critical position of the power grid. Other benefits include the possibility of repeatable and safe measurement.cs
dc.format.extent1225679 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoencs
dc.publisherBudapesti Muszaki es Gazdasagtudomanyi Egyetemcs
dc.relation.ispartofseriesPeriodica Polytechnica Civil Engineeringcs
dc.relation.urihttps://doi.org/10.3311/PPci.11253cs
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/cs
dc.subjectgeodetic surveycs
dc.subjectFOTOMcs
dc.subjectimage processingcs
dc.subjectradon transformcs
dc.subjectperspective transformcs
dc.subjectdigital photogrammetrycs
dc.titleMonitoring of excessive deformation of steel structure Extra-High Voltage pylonscs
dc.typearticlecs
dc.identifier.doi10.3311/PPci.11253
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume62cs
dc.description.issue2cs
dc.description.lastpage329cs
dc.description.firstpage323cs
dc.identifier.wos000432598700005


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

http://creativecommons.org/licenses/by/3.0/
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je http://creativecommons.org/licenses/by/3.0/