dc.description.abstract | The present article describes the diagnostics of a compressor that is compressing a mixture of H-2 and N-2 on the basis of the results that were obtained by operational measurements of the flow rates and temperatures at selected compressor sites, as well as of the acoustic pressure levels during the full loading thereof. The obtained data were subsequently used to determine the limit conditions of the compressor operations in terms of the cooling capacity. A thermodynamic analysis of the compression of the H-2/N-2 gas mixture was carried out with subsequent heat and energy flow calculation and the determination of the minimum cooling water flow rate that is required to ensure the continuous compressor operations. | cs |
dc.format.extent | 20026078 bytes | |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | cs |
dc.publisher | MDPI | cs |
dc.relation.ispartofseries | Applied Sciences | cs |
dc.relation.uri | https://doi.org/10.3390/app8040625 | cs |
dc.rights | © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license. | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | cs |
dc.subject | compressor | cs |
dc.subject | diagnostics | cs |
dc.subject | operating experiment | cs |
dc.subject | minimum cooling capacity | cs |
dc.title | Diagnostics of hydrogen-containing mixture compression by a two-stage piston compressor with cooling demand prediction | cs |
dc.type | article | cs |
dc.identifier.doi | 10.3390/app8040625 | |
dc.rights.access | openAccess | cs |
dc.type.version | publishedVersion | cs |
dc.type.status | Peer-reviewed | cs |
dc.description.source | Web of Science | cs |
dc.description.volume | 8 | cs |
dc.description.issue | 4 | cs |
dc.description.firstpage | art. no. 625 | cs |
dc.identifier.wos | 000434996400152 | |