Zobrazit minimální záznam

dc.contributor.authorBibbo, Daniele
dc.contributor.authorKlinkovský, Tomáš
dc.contributor.authorPenhaker, Marek
dc.contributor.authorKudrna, Petr
dc.contributor.authorPeter, Lukáš
dc.contributor.authorAugustynek, Martin
dc.contributor.authorKašík, Vladimír
dc.contributor.authorKubíček, Jan
dc.contributor.authorSelamat, Ali
dc.contributor.authorČerný, Martin
dc.contributor.authorBielčik, Daniel
dc.date.accessioned2020-10-12T13:02:52Z
dc.date.available2020-10-12T13:02:52Z
dc.date.issued2020
dc.identifier.citationSensors. 2020, vol. 20, issue 15, art. no. 4139.cs
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10084/142300
dc.description.abstractIn this paper, a new approach for the periodical testing and the functionality evaluation of a fetal heart rate monitor device based on ultrasound principle is proposed. The design and realization of the device are presented, together with the description of its features and functioning tests. In the designed device, a relay element, driven by an electric signal that allows switching at two specific frequencies, is used to simulate the fetus and the mother's heartbeat. The simulator was designed to be compliant with the standard requirements for accurate assessment and measurement of medical devices. The accuracy of the simulated signals was evaluated, and it resulted to be stable and reliable. The generated frequencies show an error of about 0.5% with respect to the nominal one while the accuracy of the test equipment was within +/- 3% of the test signal set frequency. This value complies with the technical standard for the accuracy of fetal heart rate monitor devices. Moreover, the performed tests and measurements show the correct functionality of the developed simulator. The proposed equipment and testing respect the technical requirements for medical devices. The features of the proposed device make it simple and quick in testing a fetal heart rate monitor, thus providing an efficient way to evaluate and test the correlation capabilities of commercial apparatuses.cs
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesSensorscs
dc.relation.urihttp://doi.org/10.3390/s20154139cs
dc.rights© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectfetal heart ratecs
dc.subjectcardiotocographcs
dc.subjectdoppler effectcs
dc.subjectheart movement simulatorcs
dc.subjecttests of medical devicecs
dc.subjectfetal heart rate monitor devicecs
dc.titleA new approach for testing fetal heart rate monitorscs
dc.typearticlecs
dc.identifier.doi10.3390/s20154139
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume20cs
dc.description.issue15cs
dc.description.firstpageart. no. 4139cs
dc.identifier.wos000559132500001


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.