Zobrazit minimální záznam

dc.contributor.authorKozielová, Marie
dc.contributor.authorMynarzová, Lucie
dc.contributor.authorMynarčík, Petr
dc.date.accessioned2021-02-01T10:40:46Z
dc.date.available2021-02-01T10:40:46Z
dc.date.issued2020
dc.identifier.citationSustainability. 2020, vol. 12, issue 22, art. no. 9474.cs
dc.identifier.issn2071-1050
dc.identifier.urihttp://hdl.handle.net/10084/142618
dc.description.abstractOne of the options for rehabilitating existing masonry buildings is a post-tensioning of masonry. The deformation properties of the masonry in the direction parallel to bed joints are essential for the design of a suitable value of the applied force. However, these values are usually not available or are defined only roughly. The aim of this study was to determine, as accurately as possible, the deformation characteristics of the masonry in the direction parallel to the bed joints. Experimental measuring of masonry samples was carried out in laboratory facilities designed specifically for testing the triaxial state of stress of the masonry. The obtained deformations were used to determine the modulus of elasticity of the masonry in the direction of bed joints. Within these experimental tests, laboratory measuring of mechanical masonry properties was carried out, and deformation characteristics were defined on the basis of calculations. The strengths of masonry units and mortar were tested in the laboratory and, according to the tests results, the modulus of elasticity in the direction perpendicular to bed joints was determined. The modulus of elasticity in the direction parallel to bed joints was verified through a simple numerical model. The calculated deformations were compared with the measured values. On the basis of the determination of the deformation characteristics of masonry in the direction of bed joints, the ratios of the modulus of elasticity in the direction perpendicular and parallel to bed joints were concluded.cs
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesSustainabilitycs
dc.relation.urihttp://doi.org/10.3390/su12229474cs
dc.rights© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectmasonrycs
dc.subjectbrickcs
dc.subjectmortarcs
dc.subjectcompressive strength of masonrycs
dc.subjectflexural strength of masonrycs
dc.subjectloading test of masonrycs
dc.subjectpost tensioncs
dc.subjectmodulus of elasticity of masonrycs
dc.titleExperimental testing of masonry subjected to concentrated load in direction of bed jointscs
dc.typearticlecs
dc.identifier.doi10.3390/su12229474
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume12cs
dc.description.issue22cs
dc.description.firstpageart. no. 9474cs
dc.identifier.wos000594557000001


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.