Show simple item record

dc.contributor.authorPolzer, Stanislav
dc.contributor.authorMan, Vojtěch
dc.contributor.authorVlachovský, Robert
dc.contributor.authorKubíček, Luboš
dc.contributor.authorKracík, Jan
dc.contributor.authorStaffa, Robert
dc.contributor.authorNovotný, Tomáš
dc.contributor.authorBurša, Jiří
dc.contributor.authorRaghavan, M. L.
dc.date.accessioned2021-03-15T11:10:40Z
dc.date.available2021-03-15T11:10:40Z
dc.date.issued2021
dc.identifier.citationJournal of the Mechanical Behavior of Biomedical Materials. 2021, vol. 114, art. no. 104181.cs
dc.identifier.issn1751-6161
dc.identifier.issn1878-0180
dc.identifier.urihttp://hdl.handle.net/10084/142959
dc.description.abstractIntroduction: Biomechanical rupture risk assessment of abdominal aortic aneurysm (AAA) requires information about failure properties of aneurysmal tissue. There are large differences between reported values. Among others, studies vary in using either axially or circumferentially oriented samples. This study investigates the effect of sample orientation on failure properties. Methods: Aneurysmal tissues from 45 patients (11 females) were harvested during open AAA repair, cut into uniaxial samples (90) and tested mechanically within 3 h. If possible, the samples were cut in both axial (49 samples) and circumferential (41 samples) directions. Wall thickness, First Piola-Kirchhoff strength P-ult and ultimate tension T-ult were recorded. Influence of sample orientation and other clinical parameters were investigated using non parametric tests. Results: Medians of Pull (values 1100 kPa for circumferential vs. 715 kPa for axial direction, p < 10(-4)) and T-ult (17.4 N/cm in circumferential vs. 11.2 N/cm in axial direction, p < 10(-4)) were significantly higher in circumferential direction. For paired data, the median of difference was 411 kPa (p < 10(-3)) in P-ult, and 7.4 N/cm < 10(-4)) in T-ult in favor of circumferential direction. Conclusions: In this first study of anisotropy in AAA wall failure properties using paired comparisons, the strength in circumferential orientation was found to be higher than in axial orientation.cs
dc.language.isoencs
dc.publisherElseviercs
dc.relation.ispartofseriesJournal of the Mechanical Behavior of Biomedical Materialscs
dc.relation.urihttp://doi.org/10.1016/j.jmbbm.2020.104181cs
dc.rights© 2020 Elsevier Ltd. All rights reserved.cs
dc.subjectabdominal aortic aneurysmcs
dc.subjectfailure propertiescs
dc.subjectmechanical testingcs
dc.subjectsample orientationcs
dc.titleFailure properties of abdominal aortic aneurysm tissue are orientation dependentcs
dc.typearticlecs
dc.identifier.doi10.1016/j.jmbbm.2020.104181
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume114cs
dc.description.firstpageart. no. 104181cs
dc.identifier.wos000608182400007


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record