Zobrazit minimální záznam

dc.contributor.authorSzurgacz, Dawid
dc.contributor.authorZhironkin, Sergey
dc.contributor.authorVöth, Stefan
dc.contributor.authorPokorný, Jiří
dc.contributor.authorSpearing, A. J. S.
dc.contributor.authorCehlár, Michal
dc.contributor.authorStempniak, Marta
dc.contributor.authorSobik, Leszek
dc.date.accessioned2021-09-07T12:26:53Z
dc.date.available2021-09-07T12:26:53Z
dc.date.issued2021
dc.identifier.citationEnergies. 2021, vol. 14, issue 11, art. no. 3258.cs
dc.identifier.issn1996-1073
dc.identifier.urihttp://hdl.handle.net/10084/145165
dc.description.abstractThe paper discusses the results of a study carried out to determine the thermal condition of a conveyor power unit using a thermal imaging camera. The tests covered conveyors in the main haulage system carrying coal from a longwall. The measurements were taken with a thermal imaging diagnostic method which measures infrared radiation emitted by an object. This technology provides a means of assessing the imminence and severity of a possible failure or damage. The method is a non-contact measuring technique and offers great advantages in an underground mine. The thermograms were analysed by comparing the temperature distribution. An analysis of the operating time of the conveyors was also carried out and the causes of the thermal condition were determined. The main purpose of the research was to detect changes in thermal state during the operation of a belt conveyor that could indicate failure and permit early maintenance and eliminate the chance of a fire. The article also discusses the construction and principle of operation of a thermal imaging camera. The findings obtained from the research analysis on determining the thermal condition of the conveyor drive unit are a valuable source of information for the mine's maintenance service.cs
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesEnergiescs
dc.relation.urihttps://doi.org/10.3390/en14113258cs
dc.rights© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectthermal imagingcs
dc.subjectbelt conveyorcs
dc.subjectdiagnosticscs
dc.subjectunderground miningcs
dc.subjectmechanical failurecs
dc.subjectpreventative maintenancecs
dc.titleThermal imaging study to determine the operational condition of a conveyor belt drive system structurecs
dc.typearticlecs
dc.identifier.doi10.3390/en14113258
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume14cs
dc.description.issue11cs
dc.description.firstpageart. no. 3258cs
dc.identifier.wos000659849600001


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.