Parameters setting of Frequency Converter PI regulation to ensure the vacuum of the milking process
dc.contributor.author | Kudělka, Jan | |
dc.contributor.author | Fryč, Jiří | |
dc.contributor.author | Slaný, Vlastimil | |
dc.contributor.author | Rouš, Robert | |
dc.contributor.author | Raj, Akshaya | |
dc.contributor.author | Martinek, Radek | |
dc.date.accessioned | 2021-10-11T10:52:02Z | |
dc.date.available | 2021-10-11T10:52:02Z | |
dc.date.issued | 2021 | |
dc.identifier.citation | PLOS One. 2021, vol. 16, issue 7, art. no. e0253427. | cs |
dc.identifier.issn | 1932-6203 | |
dc.identifier.uri | http://hdl.handle.net/10084/145309 | |
dc.description.abstract | This paper presents regulation of an asynchronous induction motor so as to create a stable vacuum milk pump using Variable Frequency Drive (VFD). Contribution includes providing information about the usage of the VFD, which regulates the activity of an asynchronous induction motor so that the vacuum pump milking machine creates stable vacuum. The paper describes the functional and time dependence of input values and output parameters of frequency converters at changing electric motor speed. For simulation and verification the milking process a mathematical model of the milking machine was created. The simulation was verified in Matlab/Simulink software. The constructed mathematical model showed symmetric regulation. Control model symmetry was verified at the laboratory of milking machine. The possibility to remove the control valve from milking equipment was proven using the measured data. It was found that constant vacuum values can be maintained. A constant vacuum can be maintained by changing vacuum pump speed. This control is of an accepted standard (ISO 5707: 2007). The power saving control values (on the milking equipment) of the VFD were positive throughout the measuring range. The performance of the milking vacuum pump is normally designed from the maximum air consumption of the milking machine at nominal vacuum (50 kPa), and a performance reserve is added to this. This means that the pump is operated between the ranges 7.53 and 15.06 dm(3) s(-1). By using a vacuum pump controlled by a VFD, power savings can be achieved from 32.50% to 54.02% compared to a control valve. | cs |
dc.language.iso | en | cs |
dc.publisher | PLOS | cs |
dc.relation.ispartofseries | PLOS One | cs |
dc.relation.uri | https://doi.org/10.1371/journal.pone.0253427 | cs |
dc.rights | © 2021 Kudělka et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. | cs |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | cs |
dc.title | Parameters setting of Frequency Converter PI regulation to ensure the vacuum of the milking process | cs |
dc.type | article | cs |
dc.identifier.doi | 10.1371/journal.pone.0253427 | |
dc.rights.access | openAccess | cs |
dc.type.version | publishedVersion | cs |
dc.type.status | Peer-reviewed | cs |
dc.description.source | Web of Science | cs |
dc.description.volume | 16 | cs |
dc.description.issue | 7 | cs |
dc.description.firstpage | art. no. e0253427 | cs |
dc.identifier.wos | 000668791400071 |
Soubory tohoto záznamu
Tento záznam se objevuje v následujících kolekcích
-
Publikační činnost VŠB-TUO ve Web of Science / Publications of VŠB-TUO in Web of Science [7798]
Kolekce obsahuje bibliografické záznamy článků akademických pracovníků VŠB-TUO publikovaných v časopisech indexovaných ve Web of Science od roku 1990 po současnost. -
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450) [396]
Kolekce obsahuje bibliografické záznamy publikační činnosti (článků) akademických pracovníků Katedry kybernetiky a biomedicínského inženýrství (450) v časopisech a v Lecture Notes in Computer Science registrovaných ve Web of Science od roku 2003 po současnost. -
OpenAIRE [5085]
Kolekce určená pro sklízení infrastrukturou OpenAIRE; obsahuje otevřeně přístupné publikace, případně další publikace, které jsou výsledkem projektů rámcových programů Evropské komise (7. RP, H2020, Horizon Europe). -
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals [6377]
Články z časopisů (od roku 2008), které v době vydání článku měly impakt faktor.
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © 2021 Kudělka et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.