Zobrazit minimální záznam

dc.contributor.authorFrydrýšek, Karel
dc.contributor.authorČepica, Daniel
dc.contributor.authorHalo, Tomáš
dc.contributor.authorSkoupý, Ondřej
dc.contributor.authorPleva, Leopold
dc.contributor.authorMadeja, Roman
dc.contributor.authorPometlová, Jana
dc.contributor.authorLosertová, Monika
dc.contributor.authorKoutecký, Jan
dc.contributor.authorMichal, Pavel
dc.contributor.authorHavlas, Vojtěch
dc.contributor.authorKraus, Šimon
dc.contributor.authorĎurica, Dominik
dc.contributor.authorPeterek Dědková, Kateřina
dc.contributor.authorPagáč, Marek
dc.contributor.authorKrpec, Pavel
dc.contributor.authorOsemlak, Paweł
dc.date.accessioned2022-06-01T09:47:15Z
dc.date.available2022-06-01T09:47:15Z
dc.date.issued2022
dc.identifier.citationApplied Sciences. 2022, vol. 12, issue 2, art. no. 614.cs
dc.identifier.issn2076-3417
dc.identifier.urihttp://hdl.handle.net/10084/146236
dc.description.abstractLimb asymmetry can, and often does, cause various health problems. Blount bone staples (clips) are used to correct such uneven growth. This article analyzes the performance of a biomechanical staple during bone (tibia) growth arrest. The staples considered in this study were made of 1.4441 stainless steel, the model of tibia consisted of two materials representing corticalis and spongiosis. Hooke's law was used for modeling materials' behaviors for finite element analysis (FEA). The maxima of stress and total staple displacement were evaluated using the finite element method and verification of the results, along with the determination of the maximum loading (growing) force that the staples are capable of withstanding, was performed experimentally. The presented method can be used to determine the safety and usability of staples for bone growth arrest. According to our results, the design of Blount staples considered in this paper is safe and suitable for orthopedic treatment.cs
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesApplied Sciencescs
dc.relation.urihttps://doi.org/10.3390/app12020614cs
dc.rights© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectbiomechanicscs
dc.subjectorthopedicscs
dc.subjectBlount staplecs
dc.subjectFEAcs
dc.subjectexperimentcs
dc.subjectepiphysiodesiscs
dc.titleBiomechanical analysis of staples for epiphysiodesiscs
dc.typearticlecs
dc.identifier.doi10.3390/app12020614
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume12cs
dc.description.issue2cs
dc.description.firstpageart. no. 614cs
dc.identifier.wos000757989600001


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.