Zobrazit minimální záznam

dc.contributor.authorMadeja, Roman
dc.contributor.authorPometlová, Jana
dc.contributor.authorOsemlak, Paweł
dc.contributor.authorVoves, Jiří
dc.contributor.authorBialy, Lubor
dc.contributor.authorVrtková, Adéla
dc.contributor.authorPleva, Leopold
dc.date.accessioned2022-10-03T06:24:40Z
dc.date.available2022-10-03T06:24:40Z
dc.date.issued2022
dc.identifier.citationEuropean Journal of Trauma and Emergency Surgery. 2022.cs
dc.identifier.issn1863-9933
dc.identifier.issn1863-9941
dc.identifier.urihttp://hdl.handle.net/10084/148661
dc.description.abstractPurpose Treatment of pelvic fractures is often complicated. Here, we intended to evaluate the intraoperative benefits of using 2D computer navigation when compared with traditional fluoroscopy on X-ray burden, surgical time and screw placement accuracy. Methods In this study, we retrospectively evaluated the records of 25 patients who underwent osteosynthesis of a posterior pelvic fracture using fluoroscopy at the University Hospital Ostrava, Czech Republic between 2011 and 2019, and 32 patients from the same department and period in whom 2D computer navigation was used. Results Intraoperative X-ray burden was significantly lower in the group with 2D computer navigation (median 650 vs 1024 cGy/cm(2)), as was the duration of the surgery (41 vs 45 min). This was most obvious where two screws were inserted (X-ray dose of 994 vs 1847 cGy/cm(2) and 48 vs 70 min, respectively). Correction of the path for wire placement after the original drilling was necessary in 2 patients (6%) from the 2D computer navigation group and 15 patients from the fluoroscopy group (60%). Still, no malposition of the screws nor dislocation of the posterior pelvic segment after 12 months was observed in any patient of either group; of complications, only three superficial infections in the 2D navigation group and 2 in the fluoroscopy group were observed. Conclusion 2D computer navigation is a safe and accurate method for placement of screws during posterior pelvic fracture osteosynthesis, associated with lower intraoperative radiation burden and shorter surgical times compared to standard fluoroscopy, especially if two screws are inserted.cs
dc.language.isoencs
dc.publisherSpringer Naturecs
dc.relation.ispartofseriesEuropean Journal of Trauma and Emergency Surgerycs
dc.relation.urihttps://doi.org/10.1007/s00068-022-02020-ycs
dc.rightsCopyright © 2022, The Author(s), under exclusive licence to Springer-Verlag GmbH Germanycs
dc.subjectpelvic fracturecs
dc.subjectscrew osteosynthesiscs
dc.subjectnavigationcs
dc.subjectfluoroscopycs
dc.subject2D computer navigationcs
dc.subjectradiation burdencs
dc.subjectiliosacral screwscs
dc.titleComparison of fluoroscopy and fluoroscopy-based 2D computer navigation for iliosacral screw placement: a retrospective studycs
dc.typearticlecs
dc.identifier.doi10.1007/s00068-022-02020-y
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.identifier.wos000821714700002