Zobrazit minimální záznam

dc.contributor.authorCzakoj, Tomáš
dc.contributor.authorKošt́ál, Michal
dc.contributor.authorZmeškal, Marek
dc.contributor.authorNovák, Evžen
dc.contributor.authorMravec, Filip
dc.contributor.authorCvachovec, František
dc.contributor.authorŠimon, Jan
dc.contributor.authorSchulc, Martin
dc.contributor.authorUhlář, Radim
dc.contributor.authorAlexa, Petr
dc.contributor.authorMatěj, Zdeněk
dc.date.accessioned2022-10-03T08:48:48Z
dc.date.available2022-10-03T08:48:48Z
dc.date.issued2022
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2022, vol. 1034, art. no. 166837.cs
dc.identifier.issn0168-9002
dc.identifier.issn1872-9576
dc.identifier.urihttp://hdl.handle.net/10084/148666
dc.description.abstractUsing D-T generators as a neutron source for precise measurements requests a well-known neutron spectrum and spatial distribution of neutron flux. It is important in cross section measurements as well as in deep penetration issues. Thus, it is very important not only to validate the fluence accurately but also accurately validate the neutron spectrum in various positions. Experimental validation of two different D-T neutron generator experiments was performed using proton recoil method. Measurements performed at different angles and neutron generator voltages show relatively good agreement with the calculations. Despite the poor resolution, it was shown that stilbene is usable for the measurement of neutron energy shift due to changes in deuteron voltage.cs
dc.language.isoencs
dc.publisherElseviercs
dc.relation.ispartofseriesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipmentcs
dc.relation.urihttps://doi.org/10.1016/j.nima.2022.166837cs
dc.rights© 2022 Elsevier B.V. All rights reserved.cs
dc.subjectneutron D–T generatorcs
dc.subjectstilbenecs
dc.subjectgeantcs
dc.subjectneutron spectrumcs
dc.subjectfusion neutronscs
dc.titleThe characterization of D–T neutron generators in precise neutron experimentscs
dc.typearticlecs
dc.identifier.doi10.1016/j.nima.2022.166837
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume1034cs
dc.description.firstpageart. no. 166837cs
dc.identifier.wos000829843400013


Soubory tohoto záznamu

SouboryVelikostFormátZobrazit

K tomuto záznamu nejsou připojeny žádné soubory.

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam