Zobrazit minimální záznam

dc.contributor.authorBarvík, Daniel
dc.contributor.authorČerný, Martin
dc.contributor.authorNoury, Norbert
dc.date.accessioned2024-01-23T11:51:09Z
dc.date.available2024-01-23T11:51:09Z
dc.date.issued2023
dc.identifier.citationIEEE Transactions on Instrumentation and Measurement. 2023, vol. 72, art. no. 4001208.cs
dc.identifier.issn0018-9456
dc.identifier.issn1557-9662
dc.identifier.urihttp://hdl.handle.net/10084/151946
dc.description.abstractThis article investigates a prospective capacitive sensing method for the measurement of physical characteristics of a pulsatile liquid flow. It was tested on a physical vascular model. The volume pulse wave sensor holds a high sensitivity and thus great potential in the field of industrial applications and also in biomedical applications where we also encounter a pulsating flow of blood. Two types of capacity sensors were developed and tested on our blood vessel model, currently used for the simulation of pulse wave propagation with the possibility of changes in vessel properties and many setups are reached for testing different pulse wave propagations. The newly developed capacitive sensor detects the capacity change of pulsating liquid flow in the vascular model. Data from the capacitive sensor are compared with two reference sensors, one for direct pressure sensing and the second for noncontact optical sensing of changes in diameter. The signal processing is used for all three types of sensors and analysis in the time and frequency domain to determine the accuracy. The use of capacitive sensors is promising since it can measure a negligible change in the diameter of the vessel in the range of tens of femtofarads (fF). We can confirm that the high precision measurement is dependent on the environment, which can cause the capacity change, but with proper shielding it can be eliminated.cs
dc.language.isoencs
dc.publisherIEEEcs
dc.relation.ispartofseriesIEEE Transactions on Instrumentation and Measurementcs
dc.relation.urihttps://doi.org/10.1109/TIM.2022.3230478cs
dc.rightsCopyright © 2023, IEEEcs
dc.subjectblood vessel modelcs
dc.subjectcapacitive measurementcs
dc.subjectfluid flowcs
dc.subjectpulse wavecs
dc.subjectsemi-cylindrical sensorscs
dc.titleThe capacitive sensing of the pulsatile liquid flow - Investigation on a physical vascular modelcs
dc.typearticlecs
dc.identifier.doi10.1109/TIM.2022.3230478
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume72cs
dc.description.firstpageart. no. 4001208cs
dc.identifier.wos000922147200093


Soubory tohoto záznamu

SouboryVelikostFormátZobrazit

K tomuto záznamu nejsou připojeny žádné soubory.

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam