dc.contributor.author | Košt́ál, Michal | |
dc.contributor.author | Czakoj, Tomáš | |
dc.contributor.author | Alexa, Petr | |
dc.contributor.author | Šimon, Jan | |
dc.contributor.author | Zmeškal, Marek | |
dc.contributor.author | Schulc, Martin | |
dc.contributor.author | Krechlerová, Alena | |
dc.contributor.author | Peltán, Tomáš | |
dc.contributor.author | Mravec, Filip | |
dc.contributor.author | Cvachovec, František | |
dc.contributor.author | Rypar, Vojtěch | |
dc.contributor.author | Uhlář, Radim | |
dc.contributor.author | Harkut, Ondřej | |
dc.contributor.author | Matěj, Zdeněk | |
dc.date.accessioned | 2024-02-15T12:07:36Z | |
dc.date.available | 2024-02-15T12:07:36Z | |
dc.date.issued | 2023 | |
dc.identifier.citation | Annals of Nuclear Energy. 2023, vol. 191, art. no. 109904. | cs |
dc.identifier.issn | 0306-4549 | |
dc.identifier.issn | 1873-2100 | |
dc.identifier.uri | http://hdl.handle.net/10084/152189 | |
dc.description.abstract | This paper deals with the measurement of the differential dosimetry cross sections using a small compact D-T neutron generator with 14.05 ± 0.08 MeV neutron emission (1 × 108 n/s into 4π). In spite of low neutron flux, it is possible to get measurable gamma-ray activities by irradiating a larger amount of target material placed in close geometry. The experimentally determined cross sections are in good agreement with the cross sections in the IRDFF-II dosimetry library. The comparison with other nuclear data libraries was performed as well. It is worth noting that the mean standard deviation in IRDFF-II library is about 4 %, while in the case of other data libraries they are from 5.5 % to 7.5 %. This result can be understood as a validation of IRDFF-II using 14.05 MeV neutrons and also a confirmation of the applicability of small compact generators in the measurement of activation cross sections. | cs |
dc.language.iso | en | cs |
dc.publisher | Elsevier | cs |
dc.relation.ispartofseries | Annals of Nuclear Energy | cs |
dc.relation.uri | https://doi.org/10.1016/j.anucene.2023.109904 | cs |
dc.rights | © 2023 Elsevier Ltd. All rights reserved. | cs |
dc.subject | cross section measurement | cs |
dc.subject | D-T generator | cs |
dc.subject | neutron dosimetry | cs |
dc.subject | sample irradiation | cs |
dc.title | Measurement of dosimetrical cross sections with 14.05 MeV neutrons from compact neutron generator | cs |
dc.type | article | cs |
dc.identifier.doi | 10.1016/j.anucene.2023.109904 | |
dc.type.status | Peer-reviewed | cs |
dc.description.source | Web of Science | cs |
dc.description.volume | 191 | cs |
dc.description.firstpage | art. no. 109904 | cs |
dc.identifier.wos | 001007327400001 | |