Analysis on population-based algorithm optimized filter for non-invasive fECG extraction
dc.contributor.author | Kong, Lingping | |
dc.contributor.author | Mirjalili, Seyedali | |
dc.contributor.author | Snášel, Václav | |
dc.contributor.author | Pan, Jeng-Shyang | |
dc.contributor.author | Raj, Akshaya | |
dc.contributor.author | Vilímková Kahánková, Radana | |
dc.contributor.author | Martinek, Radek | |
dc.date.accessioned | 2024-03-06T11:08:12Z | |
dc.date.available | 2024-03-06T11:08:12Z | |
dc.date.issued | 2023 | |
dc.identifier.citation | Applied Soft Computing. 2023, vol. 142, art. no. 110323. | cs |
dc.identifier.issn | 1568-4946 | |
dc.identifier.issn | 1872-9681 | |
dc.identifier.uri | http://hdl.handle.net/10084/152291 | |
dc.description.abstract | Metaheuristic algorithms (MAs) have become one of the primary tools for optimization in diverse domains, including non-invasive fetal electrocardiogram (fECG) extraction. Research reveals that hyperparameters affect the performance of MAs differently to problems, and some algorithms are problem-specific designed and may produce bad results for different problems. Hence, three questions arise, (1) how much can we trust MAs when solving boxed-constrained fECG extraction problems, and (2) which type of MAs are suitable and adequate for fECG extraction? (3) do MAs find acceptable solutions to a problem that does not formulate the problem comprehensively with an imperfect objective function? This paper focuses on these three inquiries and proposes a framework providing an MA-assisted adaptive filter for non-invasive fECG extraction. The proposed framework has three key components: data pre-processing, MA-based adaptive filter, and post-processing. The pre-processing starts to process the signals detected by pregnant women and extract the desired signal by independent component analysis. Such output signals are then passed to a filter and optimized by population -based algorithms, producing an optimal solution. After that, this solution, as filter weights, will be used for signal extraction and be processed by post-processing. Importantly, the proposed framework is user-friendly that can import any MA algorithm to run and disassemble as a separate assisting tool. This work investigated eight classic and disparate MA algorithms on the Abdominal and Direct Fetal ECG Database (ADFECGDB) dataset, offering comprehensive experimental analysis. We infer from the results that the recordings r01, r02, r03, r05, r08, and r09, where the signals are less noisy and can be solved well. While for recordings r04, r07, r06, and r10, the performance can be influenced by hyperparameters for any test algorithms, such as the population size, window size, and other parameters in MAs. Meanwhile, we found that MA may not be the primary target influencing the performance vary. | cs |
dc.language.iso | en | cs |
dc.publisher | Elsevier | cs |
dc.relation.ispartofseries | Applied Soft Computing | cs |
dc.relation.uri | https://doi.org/10.1016/j.asoc.2023.110323 | cs |
dc.rights | © 2023 Elsevier B.V. All rights reserved. | cs |
dc.subject | evolutionary algorithm | cs |
dc.subject | fetal signal extraction | cs |
dc.subject | least mean square filter | cs |
dc.subject | population-based optimization | cs |
dc.subject | independent component analysis | cs |
dc.subject | non-invasive fetal ECG extraction | cs |
dc.title | Analysis on population-based algorithm optimized filter for non-invasive fECG extraction | cs |
dc.type | article | cs |
dc.identifier.doi | 10.1016/j.asoc.2023.110323 | |
dc.type.status | Peer-reviewed | cs |
dc.description.source | Web of Science | cs |
dc.description.volume | 142 | cs |
dc.description.firstpage | art. no. 110323 | cs |
dc.identifier.wos | 001052889400001 |
Soubory tohoto záznamu
Soubory | Velikost | Formát | Zobrazit |
---|---|---|---|
K tomuto záznamu nejsou připojeny žádné soubory. |
Tento záznam se objevuje v následujících kolekcích
-
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals [6377]
Články z časopisů (od roku 2008), které v době vydání článku měly impakt faktor. -
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450) [396]
Kolekce obsahuje bibliografické záznamy publikační činnosti (článků) akademických pracovníků Katedry kybernetiky a biomedicínského inženýrství (450) v časopisech a v Lecture Notes in Computer Science registrovaných ve Web of Science od roku 2003 po současnost. -
Publikační činnost Katedry informatiky / Publications of Department of Computer Science (460) [562]
Kolekce obsahuje bibliografické záznamy publikační činnosti (článků) akademických pracovníků Katedry informatiky (460) v časopisech a v Lecture Notes in Computer Science registrovaných ve Web of Science od roku 2003 po současnost. -
Publikační činnost VŠB-TUO ve Web of Science / Publications of VŠB-TUO in Web of Science [7798]
Kolekce obsahuje bibliografické záznamy článků akademických pracovníků VŠB-TUO publikovaných v časopisech indexovaných ve Web of Science od roku 1990 po současnost.