Zobrazit minimální záznam

dc.contributor.authorPříhoda, Miroslav
dc.contributor.authorMolínek, Jiří
dc.contributor.authorPyszko, René
dc.contributor.authorVelička, Marek
dc.contributor.authorVaculík, Miroslav
dc.contributor.authorBurda, Jiří
dc.date.accessioned2009-09-25T06:56:05Z
dc.date.available2009-09-25T06:56:05Z
dc.date.issued2009
dc.identifier.citationMetalurgija. 2009, g. 48, br. 4, s. 235-238.en
dc.identifier.issn0543-5846
dc.identifier.issn1334-2576
dc.identifier.urihttp://hdl.handle.net/10084/76073
dc.description.abstractMethod of cooling in a secondary zone of continuous casting of steel has a significant influence on a quality of continuously cast products mainly from the point of view of internal and surface defects as well as zonal segregations. At the department of thermal engineering, a physical model of the secondary zone has been developed, which enables testing of both water and water-air nozzles. During laboratory measurements cooling effects of a cone nozzle have been expressed by means of three parameters. Most commonly used parameter is an admission characteristic, infrequently heat transfer coefficient is determined and newly a measuring of dynamic impact of the cooling water has been introduced.en
dc.format.extent1267246 bytescs
dc.format.mimetypeapplication/pdfcs
dc.language.isoenen
dc.publisherHrvatsko Metalurško Društvoen
dc.relation.ispartofseriesMetalurgijaen
dc.relation.urihttp://hrcak.srce.hr/file/60781en
dc.subjectheat transfer coefficienten
dc.subjectcooling of surfaceen
dc.subjectnozzleen
dc.subjectcontinuous casting of steelen
dc.subjectkoeficijent prijenosa toplineen
dc.subjecthladenje površineen
dc.subjectsapnicaen
dc.subjectkontinuirano lijevanje čelikaen
dc.titleHeat transfer during cooling of hot surfaces by water nozzlesen
dc.title.alternativePrijenos topline tijekom hla|enja vrućih površina pomoću vodenih sapnicaen
dc.typearticleen
dc.identifier.locationNení ve fondu ÚKen
dc.description.abstract-enTijekom kontinuiranog lijevanja čelika, hladenje sekundarne zone od značajnog je utjecaja na kvalitetu odljevaka sa aspekta unutraš njih i površinskih pogrešaka te u kontekstu zonske segregacije u materijalu. U odjelu za termoenergetiku razvijen je fizikalni model sekundarne zone, kojim je omogućeno ispitivanje vodenih sapnica i sapnica za hladenje mješavinom vode i zraka. Tijekom laboratorijskih mjerenja, efekti hladenja koničnom sapnicom izraženi su trima parametrima. Nejčešći je pritom parameter admisijske karakteristike, ponekad se odreduje i koeficijent prijelaza topline a recentno je uvedeno mjerenje dinamičkog utjecaja rashladne vode.en
dc.rights.accessopenAccess
dc.type.versionpublishedVersion
dc.identifier.wos000267255800005