Zobrazit minimální záznam

dc.contributor.authorFraňová, Miroslava
dc.contributor.authorRepáková, Jarmila
dc.contributor.authorČapková, Pavla
dc.contributor.authorHolopainen, Juha M.
dc.contributor.authorVattulainen, Ilpo
dc.date.accessioned2010-03-15T08:03:27Z
dc.date.available2010-03-15T08:03:27Z
dc.date.issued2010
dc.identifier.citationJournal of Physical Chemistry B. 2010, vol. 114, issue 8, s. 2704-2711.en
dc.identifier.issn1520-6106
dc.identifier.issn1520-5207
dc.identifier.urihttp://hdl.handle.net/10084/78211
dc.description.abstractWe have used atomistic molecular dynamics simulations to consider 1,6-diphenyl-1,3,5-hexatriene (DPH) fluorescent probes in a fluid dipalmitoylphosphatidylcholine bilayer with 5 and 20 mol % cholesterol (CHOL). We show that while DPH affects a number of membrane properties, the perturbations induced by DPH depend on the concentration of cholesterol in a membrane. For example, we find DPH to influence the mass density distribution of lipids across the membrane and to promote the ordering of acyl chains around the probe. Yet, these perturbations get relatively weaker for increasing cholesterol concentration. Meanwhile, we also find that the commonly used analysis in terms of the Brownian rotational diffusion (BRD) model with Legendre polynomials to interpret fluorescence anisotropy (FA) experiments is sensitive to the amount of cholesterol. For small concentrations of cholesterol, the analysis of FA turns out to yield a relatively good approximation of the correct orientational distribution of DPH. However, for a CHOL concentration of 20 mol %, we find that the FA analysis fails to yield the true orientational distribution of DPH, the disagreement being substantial. The results suggest that in highly ordered membrane domains, the view given by FA analysis using the BRD model is likely reliable in a qualitative sense, but the quantitative description deviates substantially from the correct one. The present results imply that FA studies for the orientational distribution of DPH should be interpreted with great care.en
dc.language.isoenen
dc.publisherAmerican Chemical Societyen
dc.relation.ispartofseriesJournal of Physical Chemistry Ben
dc.relation.urihttps://doi.org/10.1021/jp908533xen
dc.titleEffects of DPH on DPPC-cholesterol membranes with varying concentrations of cholesterol: from local perturbations to limitations in fluorescence anisotropy experimentsen
dc.typearticleen
dc.identifier.locationNení ve fondu ÚKen
dc.identifier.doi10.1021/jp908533x
dc.identifier.wos000274842600019


Soubory tohoto záznamu

SouboryVelikostFormátZobrazit

K tomuto záznamu nejsou připojeny žádné soubory.

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam