Zobrazit minimální záznam

dc.contributor.authorCipryan, Lukáš
dc.contributor.authorLitschmannová, Martina
dc.date.accessioned2013-03-11T12:42:16Z
dc.date.available2013-03-11T12:42:16Z
dc.date.issued2013
dc.identifier.citationJournal of Sports Sciences. 2013, vol. 31, issue 2, p. 150-158.cs
dc.identifier.issn0264-0414
dc.identifier.issn1466-447X
dc.identifier.urihttp://hdl.handle.net/10084/96193
dc.description.abstractAt present, analysis of heart rate variability (HRV) is becoming widely used as a clinical or research tool. Supported reliability studies for HRV measurement are, however, still limited. The main purpose was to perform an assessment of the absolute and relative reliability of HRV parameters from short-term recordings by means of orthoclinostatic stimulation and to investigate, whether there is a difference in repeating the retest immediately or after several days. The study group consisted of 99 participants (mean age 22 ± 1.24 years). Standard HRV indexes were computed: PT (total spectral power), PHF (high frequency spectral power), PLF (low frequency spectral power) and LF/HF. Absolute reliability was assessed by the standard error of measurement and 95% limits of agreement; relative reliability was assessed by the intraclass correlation coefficient. There was also an estimate of the sample size needed to detect the mean difference ≥ 30% of the between-subject standard deviation. In conclusion, a large random variation (within individuals) of HRV parameters was revealed, regardless of whether the retest was repeated immediately or with an interruption. For most HRV parameters (particularly in the immediately repeated test-retest), however, random variation represents a limited portion of the between-subject variability.cs
dc.language.isoencs
dc.publisherTaylor & Franciscs
dc.relation.ispartofseriesJournal of Sports Sciencescs
dc.relation.urihttps://doi.org/10.1080/02640414.2012.721931cs
dc.subjectheart rate variabilitycs
dc.subjectreliabilitycs
dc.subjectautonomic nervous systemcs
dc.subjecttest-retestcs
dc.subjectorthoclinostaticcs
dc.titleIntra-day and inter-day reliability of heart rate variability measurementcs
dc.typearticlecs
dc.identifier.locationNení ve fondu ÚKcs
dc.identifier.doi10.1080/02640414.2012.721931
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume31cs
dc.description.issue2cs
dc.description.lastpage158cs
dc.description.firstpage150cs
dc.identifier.wos000314351400004


Soubory tohoto záznamu

SouboryVelikostFormátZobrazit

K tomuto záznamu nejsou připojeny žádné soubory.

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam