Determination of chlorite in drinking water by on-line coupling of capillary isotachophoresis and capillary zone electrophoresis

Loading...
Thumbnail Image

Downloads

0

Date issued

Authors

Praus, Petr

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Location

Není ve fondu ÚK

Signature

Abstract

An isotachophoresis (ITP)-capillary zone electrophoresis (CZE) combination was used for the determination of chlorite in drinking waters. No sample preparation is needed and no interfering by other anions in tap water was observed. The reached limits of detection with conductivity detector were 0.012-0.017 mg l(-1). By four-fold sample loading with a 30 mul valve, 0.005 mg l(-1) of chlorite was determined with R.S.D. = 3.3%. The concentrations of 0.05 and 0.20mg l(-1) were measured with R.S.D. of 2.2 and 2.7%, respectively. The recoveries of chlorite from drinking water were 96-106% in the range of 0.02-0.20 mg l(-1). The R.S.D. values of migration times (inter-day) were up to 1.3%. The time for analysis is about 15 min.

Description

Subject(s)

water analysis, chlorite, isotachophoresis-capillary zone electrophoresis

Citation

Talanta. 2004, vol. 62, issue 5, p. 977-982.