The current article deals with the determination of fire parameters of ground sweet pepper
(GSP) dust cloud. The minimum ignition temperature was determined in accordance
with STN EN ISO/IEC 80079-20-2:2016 Standard Explosive atmospheres - Part
20-2, using a Godbert-Greenwald furnace apparatus with various dust concentrations,
particle sizes, and dust-dispersion-air pressure (10 kPa, 30 kPa and 50 kPa). Three set of
different particle size ranges of GSP powder were tested during the experiment, that is,
90 to<150 μm, 150 to<200 μm, 200 to<250 μm. The MIT depends on the particle size
and varied by a maximum of 30 K, and values for the individual samples of GSP was in
the range 550 - 610 °C. Minimum ignition temperature of the GSP powder was 550 °C
(90 to<150 μm, 0.5 g and 50 kPa).