The aim of this project is to design a plan for construction in order to achieve efficient operation and then into design efficient way of heating. The heating system was designed underfloor hot water with the possibility of reheating using electric heating ladders installed in critical areas. Heat loss of the building covers condensing boiler. Part of this work is the design documentation of the building together with a technical report. Analogy is solved part of the heating, complimented by Annex with the necessary calculations for the proper design of the heating system.
The heat loss of the house ventilation and transmittance is 5 kW, covering it with condensing boiler Geminox THRS 1-10c, the energy required for water heating was set to 1 kW. Designed to preheat water solar collector Thermo HP 400/450 with a total area of 7 m2, 70 pieces of tubes.
Description
Import 05/08/2014
Subject(s)
underfloor heating, condensing boiler, the building envelope, sollar colector