Analysing of sealing properties on a bolted joint with a steel gasket by using finite element method

dc.contributor.authorMaťas, Martin
dc.contributor.authorNovák, Pavol
dc.contributor.authorBalco, Pavol
dc.date.accessioned2017-01-23T08:11:05Z
dc.date.available2017-01-23T08:11:05Z
dc.date.issued2014
dc.description.abstractThis article deals with study of contact pressure/gap distribution on a bolted joint of a hydrostatic transmission. The study was performed via numerical analyses with support of ANSYS a finite element method software package. The main focus in the results evaluation is aimed on evaluation of the contact pressure/gap on the bolted joint after tightening individual bolts and after applying operational loads on the hydrostatic unit. Operational loads in the analyses were represented by applying of an operational pressure into the individual areas of the unit. The operational pressure was applied in two time steps of the Finite Element Method analysis to simulate normal and reverse mode of the hydrostatic transmission. Numerical results were verified through experimental measurements carried out by using FujiFilm tests.cs
dc.description.abstract-enTento článok sa zaoberá skúmaním rozloženia kontaktného tlaku resp. kontaktnej vôle skrutkového spoja hydrostatického prevodníka. Skúmanie týchto ukazovateľov bolo realizované numerickými analýzami s využitím konečno-prvkového softvéru ANSYS Workbench. Cieľom príspevku je vyhodnotenie kontaktného tlaku/vôle skrutkového spoja po uťahovaní jednotlivých skrutiek a po aplikácii prevádzkového zaťaženia hydrostatickej jednotky. Prevádzkové zaťaženie v analýzach predstavovalo aplikáciu prevádzkového tlaku do jednotlivých oblastí jednotky. Pracovný tlak bol aplikovaný v dvoch časových krokoch konečno- prvkovej analýzy, nakoľko bol simulovaný normálny a reverzný chod hydrostatického prevodníka. Numerické výsledky boli následne porovnané s experimentálnymi meraniami, ktoré boli vykonané pomocou FujiFilm testov.cs
dc.format.extent1013267 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.citationSborník vědeckých prací Vysoké školy báňské - Technické univerzity Ostrava. Řada strojní. 2014, roč. 60, č. 1, s. 77-85 : il.cs
dc.identifier.doi10.22223/tr.2014-1/1981
dc.identifier.issn1210-0471
dc.identifier.urihttp://hdl.handle.net/10084/116798
dc.language.isoencs
dc.publisherVysoká škola báňská - Technická univerzita Ostravacs
dc.relation.ispartofseriesSborník vědeckých prací Vysoké školy báňské - Technické univerzity Ostrava. Řada strojnícs
dc.relation.urihttp://transactions.fs.vsb.cz/2014-1/1981.pdfcs
dc.rights© Vysoká škola báňská - Technická univerzita Ostravacs
dc.rights.accessopenAccess
dc.subjecthydrostatic transmissioncs
dc.subjecttightnesscs
dc.subjectcontact pressurecs
dc.subjectgasket sealingcs
dc.subjectbolted jointcs
dc.subjectFEMcs
dc.subjectFujiFilm testcs
dc.subjectexperimentscs
dc.titleAnalysing of sealing properties on a bolted joint with a steel gasket by using finite element methodcs
dc.title.alternativeAnalyzovanie tesniacých vlastností skrutkového spoja s oceľovým tesnením použitím metódy konečných prvkovcs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
1981.pdf
Size:
989.52 KB
Format:
Adobe Portable Document Format
Description:
publishedVersion

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: