Porovnání vlivu vybraných prostředků do myček na nádobí na respirační inhibici aktivačního kalu

Loading...
Thumbnail Image

Downloads

4

Date issued

Journal Title

Journal ISSN

Volume Title

Publisher

Vysoká škola báňská - Technická univerzita Ostrava

Location

Signature

Abstract

This thesis solves the effects of selected dishwashing detergents on respiration inhibition of microorganisms in activated sludge from waste water treatment plants. Measurement was running on activated sludge from two Ostrava waste water treatment plants – on WWTP Ostrava and WWTP Michálkovice. The both of these WWTP belong to OVAK, a.s. Respiration inhibition was measured by means of Strathtox unit (Strathkelvin Instruments Ltd.). It was proved in this thesis that microorganisms in astivated sludge have different sensitivity determined by measuring the respiration inhibition. Activated sludge from WWTP Ostrava is less sensitive for higher concentrations of pollutants.

Description

Subject(s)

Activated sludge, respiration, respiration inhibition, Strathtox, dishwashing detergents, waste water treatment plants

Citation