dc.description.abstractGround-supported tanks are used to store a variety of liquids. During earthquake activity the liquid exerts impulsive and convective pressures (sloshing) on the walls and bottom of the rectangular tank. This paper provides theoretical background for analytical calculating of circular frequencies and hydrodynamic pressures developed during an earthquake in rectangular container. Analytical results of first natural frequency are compared with experimenten