Numerical Analysis and Simulation of Rogowski Coil
| dc.contributor.advisor | Kačor, Petr | |
| dc.contributor.author | Hussion, M Walid | |
| dc.contributor.referee | Fulneček, Jan | |
| dc.date.accepted | 2019-05-28 | |
| dc.date.accessioned | 2019-09-26T07:34:50Z | |
| dc.date.available | 2019-09-26T07:34:50Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | This work illustrates an analysis of Rogowski coils for power applications, when operating under non ideal measurement conditions. The developed numerical model, validated by comparison with other methods and experiments, enables to investigate the effects of the geometrical and constructive parameters on the measurement behavior of the coil and we also study the behavior of Rogowski coils coupled with bar conductors under quasi-static conditions. Through a finite element (FEM) analysis, we estimate the current distribution across the bar and the flux linked by the transducer for various positions of the primary conductor and for various operating frequencies. Simulation and experimental results are reported in the text. | en |
| dc.description.abstract | Tato práce ilustruje analýzu rogowských cívek pro energetické aplikace při provozu v podmínkách bez ideálního měření. Vyvinutý numerický model, ověřený porovnáním s jinými metodami a experimenty, umožňuje zkoumat vliv geometrických a konstrukčních parametrů na chování měření cívky a také studujeme chování rogowských cívek spojených s tyčovými vodiči za kvazi-statických podmínek . Pomocí analýzy konečných prvků (FEM) odhadujeme rozložení proudu přes tyč a tok spojený snímačem pro různé polohy primárního vodiče a pro různé provozní frekvence. Simulační a experimentální výsledky jsou uvedeny v textu. | cs |
| dc.description.department | 410 - Katedra elektroenergetiky | cs |
| dc.description.result | dobře | cs |
| dc.format.extent | 3796484 bytes | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.other | OSD002 | |
| dc.identifier.sender | S2724 | |
| dc.identifier.thesis | HUS0073_FEI_N2649_3907T001_2019 | |
| dc.identifier.uri | http://hdl.handle.net/10084/138713 | |
| dc.language.iso | en | |
| dc.publisher | Vysoká škola báňská - Technická univerzita Ostrava | cs |
| dc.rights.access | openAccess | |
| dc.subject | Rogowski coil, numerical model, 3D model of Rogowski,1phase and 3phase system | en |
| dc.subject | Rogowského cívka, numerický model, 3D model systému Rogowski, 1fáze a 3fáze | cs |
| dc.thesis.degree-branch | Elektroenergetika | cs |
| dc.thesis.degree-grantor | Vysoká škola báňská - Technická univerzita Ostrava. Fakulta elektrotechniky a informatiky | cs |
| dc.thesis.degree-level | Magisterský studijní program | cs |
| dc.thesis.degree-name | Ing. | |
| dc.thesis.degree-program | Elektrotechnika | cs |
| dc.title | Numerical Analysis and Simulation of Rogowski Coil | en |
| dc.title.alternative | Numerická analýza a simulace Rogowského cívky | cs |
| dc.type | Diplomová práce | cs |
Files
Original bundle
1 - 3 out of 3 results
Loading...
- Name:
- HUS0073_FEI_N2649_3907T001_2019.pdf
- Size:
- 3.62 MB
- Format:
- Adobe Portable Document Format
- Description:
- Text práce
Loading...
- Name:
- HUS0073_FEI_N2649_3907T001_2019_posudek_vedouci_Kacor_Petr.pdf
- Size:
- 48.65 KB
- Format:
- Adobe Portable Document Format
- Description:
- Posudek vedoucího – Kačor, Petr
Loading...
- Name:
- HUS0073_FEI_N2649_3907T001_2019_posudek_oponent_Fulnecek_Jan.pdf
- Size:
- 46.68 KB
- Format:
- Adobe Portable Document Format
- Description:
- Posudek oponenta – Fulneček, Jan