Nízkoenergetický rodinný dům

Loading...
Thumbnail Image

Downloads

2

Date issued

Authors

Chudý, Tomáš

Journal Title

Journal ISSN

Volume Title

Publisher

Vysoká škola báňská - Technická univerzita Ostrava

Location

Signature

Abstract

The main target of diploma work is to prove, that family house will be low-energy, project of heating and forced airing family house. Measuring requirement of heat on heating was calculated in program Energy . Value by calculation si 25 kWh/m2•a. The low-energy family house has measuring requirement of heat on heating maximum 50 kWh/m2•a. The-low energy house has average coefficient spred thought of heat Uem = 0,24 W/m2•K. For low-energy house it has to be maximum 0,35 W/m2•K. This family house is put to low-energy category. Heating of house will be ensured by heat line flor heating with added heating unit. Forced airing will be ensured by recuperation unit by Atrea company. System forced airing will be straight pressure with supply air and drainage wasted air about capacity 300 m3/h

Description

Import 15/01/2013

Subject(s)

nízoenergetický, měrná potřeba tepla na vytápění, průměrný součinitel prostupu tepla, vy-tápění, podlahové vytápění, otopná tělesa, nucené větrání, RAUCAD, KORADO, ATREA, vodovod, solární kolektor

Citation