Abstract
Based on the system approach and the
principle of electrohydrodynamic analogy, a formal-
ized mathematical model of a generalized system of
asynchronous centrifugal pumping units of a multi-unit
pumping station with an asynchronous electric drive of
centrifugal pumps was created. This model is easy to
adapt to the specific configuration of the pumping sta-
tion. A feature of the model is the use of such pa-
rameters of the centrifugal pump, which are calculated
directly through the geometric dimensions of its inter-
nal elements, taking into account the dependence of
these parameters on the physical properties of the work-
ing fluid. Unlike existing models, this makes it pos-
sible to take into account the influence of operational
or emergency changes in pump parameters and opera-
tional changes in the physical properties of the working
fluid both on its pumping regimes and on the operation
regimes of the electric drive directly during the simu-
lation. The scope of use and ways of improving the
developed model, as well as the direction of further re-
search, are proposed.