Measurement of Let-Through Energy of Low Voltage Circuit Breakers During the Disconnecting of Short Circuit Current

dc.contributor.advisorKačor, Petr
dc.contributor.authorSekar, Prasand
dc.contributor.refereeSikora, Tadeusz
dc.date.accepted2023-05-30
dc.date.accessioned2023-06-23T08:44:06Z
dc.date.available2023-06-23T08:44:06Z
dc.date.issued2023
dc.description.abstractThe abstract of the paper "Measurement of Let-Through Energy of Low Voltage Circuit Breakers During the Disconnecting of Short Circuit Current" would describe the main objectives, methodology, and findings of the study. This study aimed to investigate the let-through energy of low-voltage circuit breakers during the disconnection of short-circuit currents. To achieve this objective, the researchers conducted experiments on a sample of circuit breakers and measured the let-through energy using specialized equipment. The study found that the let-through energy of the tested circuit breakers varied depending on the type of circuit breaker and the magnitude of the short-circuit current. The results also revealed that the passthrough energy of some circuit breakers exceeded the limit specified by industry standards, indicating a potential safety hazard. These findings suggest that more research and improvements in circuit breaker design and performance are necessary to ensure safe and reliable operation in electrical power systems.en
dc.description.abstractAbstrakt článku "Měření propustné energie nízkonapěťových jističů při odpojování zkratového proudu" popisuje hlavní cíle, metodiku a výsledky studie. Cílem této studie bylo prozkoumat propustnou energii jističů nízkého napětí při odpojování zkratových proudů. K dosažení tohoto cíle výzkumníci prováděli experimenty na vzorku jističů a měřili propustnou energii pomocí specializovaného zařízení. Studie zjistila, že propustná energie testovaných jističů se liší v závislosti na typu jističe a velikosti zkratového proudu. Výsledky také odhalily, že propustná energie některých jističů přesahuje limit stanovený průmyslovými normami, což naznačuje potenciální bezpečnostní riziko. Tato zjištění naznačují, že pro zajištění bezpečného a spolehlivého provozu v elektrických rozvodných sítích je nutné provést další výzkum a zlepšit konstrukci a výkon jističů.cs
dc.description.department410 - Katedra elektroenergetikycs
dc.description.resultvýborněcs
dc.format.extent4643178 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.otherOSD002
dc.identifier.senderS2724
dc.identifier.thesisSEK0059_FEI_N0713A060004_2023
dc.identifier.urihttp://hdl.handle.net/10084/150117
dc.language.isoen
dc.publisherVysoká škola báňská – Technická univerzita Ostravacs
dc.rights.accessopenAccess
dc.subjectCircuit breakers, short circuit, released energy, instantaneous values, voltage, current, Joule's integral, trigger, pulse generator,en
dc.subjectJističe, zkrat, uvolněná energie, okamžité hodnoty, napětí, proud, Jouleův integrál, spoušť, generátor impulsů,cs
dc.thesis.degree-grantorVysoká škola báňská – Technická univerzita Ostrava. Fakulta elektrotechniky a informatikycs
dc.thesis.degree-levelMagisterský studijní programcs
dc.thesis.degree-nameIng.
dc.thesis.degree-programElektroenergetikacs
dc.titleMeasurement of Let-Through Energy of Low Voltage Circuit Breakers During the Disconnecting of Short Circuit Currenten
dc.title.alternativeMěření propuštěné energie při vypínání zkratového proudu jističem nncs
dc.typeDiplomová prácecs

Files

Original bundle

Now showing 1 - 4 out of 4 results
Loading...
Thumbnail Image
Name:
SEK0059_FEI_N0713A060004_2023.pdf
Size:
4.43 MB
Format:
Adobe Portable Document Format
Description:
Text práce
Loading...
Thumbnail Image
Name:
SEK0059_FEI_N0713A060004_2023_zadani.pdf
Size:
82.65 KB
Format:
Adobe Portable Document Format
Description:
Zadání
Loading...
Thumbnail Image
Name:
SEK0059_FEI_N0713A060004_2023_posudek_vedouci_Kacor_Petr.pdf
Size:
150.49 KB
Format:
Adobe Portable Document Format
Description:
Posudek vedoucího – Kačor, Petr
Loading...
Thumbnail Image
Name:
SEK0059_FEI_N0713A060004_2023_posudek_oponent_Sikora_Tadeusz.pdf
Size:
149.01 KB
Format:
Adobe Portable Document Format
Description:
Posudek oponenta – Sikora, Tadeusz