The goal of this work was the calibration Leica Total Station 1201 +, which is owned IGDM. For this purpose the calibration of angles and lengths in the laboratory and rangefind base in which it was intended collimation error, error in the targeting and reading while adjusting alhidádě, accuracy and range finder device Addition constant. Results are expressed as standard deviations. Part of this work is lo compare the data with the data supplied by the manufacturer. In this work, I express the measurement results with uncertainties. It is a method for evaluation of measurement errors, which is defined in CSN 01 0115. Expression of results by the uncertainties in Geodesy only introduced, but in metrology is quite normal.