Field test of mini photoionization detector-based sensors - Monitoring of volatile organic pollutants in ambient air

dc.contributor.authorBílek, Jiří
dc.contributor.authorMaršolek, Petr
dc.contributor.authorBílek, Ondřej
dc.contributor.authorBuček, Pavel
dc.date.accessioned2022-06-28T07:23:32Z
dc.date.available2022-06-28T07:23:32Z
dc.date.issued2022
dc.description.abstractThe determination of the concentrations of the organic compounds in ambient air using reference methods is a time-consuming process. The samples must be collected on a specific sorbent material and analyzed. In the best-case scenario, the analysis may be performed on site by portable chromatography techniques; otherwise, transport and laboratory analysis is necessary. Continuous sensory measurement is advantageous, especially concerning speed, resolution, price and ease of use. On the other hand, questions are raised, especially on the subject of the quality of data obtained by sensory measurements. The authors tested several types of volatile organic compound (VOC) sensors. The chosen type was deployed in a 25-unit sensor network for further testing by parallel measurements with the reference technique within the CLAIRO project.cs
dc.description.firstpageart. no. 49cs
dc.description.issue4cs
dc.description.sourceWeb of Sciencecs
dc.description.volume9cs
dc.identifier.citationEnvironments. 2022, vol. 9, issue 4, art. no. 49.cs
dc.identifier.doi10.3390/environments9040049
dc.identifier.issn2076-3298
dc.identifier.urihttp://hdl.handle.net/10084/146322
dc.identifier.wos000786880600001
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesEnvironmentscs
dc.relation.urihttps://doi.org/10.3390/environments9040049cs
dc.rights© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectsensorcs
dc.subjectelectrochemical sensorscs
dc.subjectair qualitycs
dc.subjectair pollutioncs
dc.subjectVOCcs
dc.subjectPID detectorcs
dc.titleField test of mini photoionization detector-based sensors - Monitoring of volatile organic pollutants in ambient aircs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
2076-3298-2022v9i4an49.pdf
Size:
1.06 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: