Reliability verification of an existing reinforced concrete slab

Loading...
Thumbnail Image

Downloads

4

Date issued

Journal Title

Journal ISSN

Volume Title

Publisher

Vysoká škola báňská - Technická univerzita Ostrava

Location

Signature

Abstract

The submitted contribution provides background information on the principles accepted in the CEN Technical Specification (TS). The application of the verification methods provided in the TS is clarified by an assessment of a reinforced concrete precast panel. The panel provides insufficient resistance in comparison to that required by Eurocodes for design of new structures. The critical comparison of the reliability levels indicated by Eurocodes, the assessment value method, and fully probabilistic approach demonstrates the benefits gained by applying the principles of the TS. While the partial factors recommended in Eurocodes leads to a negative result the assessment value method and the probabilistic method indicate sufficient structural reliability.

Description

Subject(s)

existing structures, partial factors, assessment values, probabilistic assessment

Citation