Propagation of partial discharge pulses in winding

dc.contributor.authorZáliš, Karel
dc.date.accessioned2011-01-19T08:44:27Z
dc.date.available2011-01-19T08:44:27Z
dc.date.issued2004
dc.description.abstractA lot of measurements of the attenuation of partial discharge pulses on the model of winding was realized in the High Voltage Laboratory of the Czech Technical University in Prague. Current pulses from a charge calibrator were injected into different parts of winding and both the distortion of the charge and their deformations at the end terminals were observed and evaluated. It was confirmed that the apparent charge of a partial discharge, as a diagnostic parameter, is not relatively very sensitive, comparing to other diagnostic parameters, e.g. to the size or the shape of a partial discharge current pulse. The charge of the partial discharge current pulse on terminals was integrated by means of three different methods. It was found that the attenuation of the partial discharge pulse is significant. It was confirmed by all three evaluating methods with similar results. Furthermore, a measurement both of the attenuation of pulse and changes of partial discharge charge was realized on different types of winding. It resulted in the fact that the attenuation of the partial discharge charge on different types of winding depends on the winding parameters.en
dc.format.extent118231 bytescs
dc.format.mimetypeapplication/pdfcs
dc.identifier.citationAdvances in electrical and electronic engineering. 2004, vol. 3, no. 3, p. 11-14.en
dc.identifier.issn1336-1376
dc.identifier.urihttp://hdl.handle.net/10084/83659
dc.language.isoenen
dc.publisherŽilinská univerzita v Žiline. Elektrotechnická fakultaen
dc.relation.ispartofseriesAdvances in electrical and electronic engineeringen
dc.relation.urihttp://advances.utc.sk/index.php/AEEEen
dc.rightsCreative Commons Attribution 3.0 Unported (CC BY 3.0)en
dc.rights© Žilinská univerzita v Žiline. Elektrotechnická fakultaen
dc.rights.accessopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/en
dc.titlePropagation of partial discharge pulses in windingen
dc.typearticleen
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
AEEE-2004-3-3-11-zalis.pdf
Size:
115.46 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.8 KB
Format:
Item-specific license agreed upon to submission
Description: