Zobrazit minimální záznam

dc.contributor.authorKazemdehdashti, Abolfazl
dc.contributor.authorSeifi, Ali Reza
dc.contributor.authorHaghighi, Amin Shabanpoor
dc.date.accessioned2013-09-30T07:21:43Z
dc.date.available2013-09-30T07:21:43Z
dc.date.issued2013
dc.identifier.citationAdvances in electrical and electronic engineering. 2013, vol. 11, no. 3, p. 174-185 : ill.cs
dc.identifier.issn1804-3119
dc.identifier.issn1336-1376
dc.identifier.urihttp://hdl.handle.net/10084/100695
dc.description.abstractIn this paper, dynamic voltage restorer (DVR) compensation methods are compared to each other for the load side connected shunt converter topology of z-source inverter based DVR to choose the best method. Four different topologies are recognized for DVR that two of them have energy storage devices, and two topologies have no energy storage that take ener\-gy from the grid during the period of compensation. Here the load side connected shunt converter topology that takes necessary energy from the grid is used. Pre-sag compensation, in-phase compensation, energy-optimized methods are the three DVR compensation methods that studied and compared. A deep analysis through different diagrams would show the advantages or disadvantages of each compensation method. Equations for all methods are derived and the characteristics of algorithms are compared with each other. The simulation results done by SIMULINK/ MATLAB shows compensating by this topology based on the compensation methods.cs
dc.format.extent749684 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoencs
dc.publisherVysoká škola báňská - Technická univerzita Ostravacs
dc.relation.ispartofseriesAdvances in electrical and electronic engineeringcs
dc.relation.urihttp://advances.utc.sk/index.php/AEEE/article/download/782/864cs
dc.rights© Vysoká škola báňská - Technická univerzita Ostrava
dc.rightsCreative Commons Attribution 3.0 Unported (CC BY 3.0)
dc.subjectcompensation methodscs
dc.subjectclose loop controlcs
dc.subjectdynamic voltage restorercs
dc.subjecttopologycs
dc.subjectZ-source invertercs
dc.titleComparison between different control strategies of a Z-source inverter based dynamic voltage restorercs
dc.typearticlecs
dc.rights.accessopenAccess
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

  • OpenAIRE [5085]
    Kolekce určená pro sklízení infrastrukturou OpenAIRE; obsahuje otevřeně přístupné publikace, případně další publikace, které jsou výsledkem projektů rámcových programů Evropské komise (7. RP, H2020, Horizon Europe).
  • AEEE. 2013, vol. 11 [58]

Zobrazit minimální záznam