Show simple item record

dc.contributor.authorOuachtouk, Ilias
dc.contributor.authorEl Hani, Soumia
dc.contributor.authorGuedira, Said
dc.contributor.authorDahi, Khalid
dc.contributor.authorSadiki, Lahbib
dc.date.accessioned2017-02-16T07:13:13Z
dc.date.available2017-02-16T07:13:13Z
dc.date.issued2016
dc.identifier.citationAdvances in electrical and electronic engineering. 2016, vol. 14, no. 5, p. 512-521 : ill.cs
dc.identifier.issn1336-1376
dc.identifier.issn1804-3119
dc.identifier.urihttp://hdl.handle.net/10084/116867
dc.description.abstractSquirrel cage induction machine are the most commonly used electrical drives, but like any other machine, they are vulnerable to faults. Among the widespread failures of the induction machine there are rotor faults. This paper focuses on the detection of broken rotor bars fault using multi-indicator. However, diagnostics of asynchronous machine rotor faults can be accomplished by analysing the anomalies of machine local variable such as torque, magnetic flux, stator current and neutral voltage signature analysis. The aim of this research is to summarize the existing models and to develop new models of squirrel cage induction motors with consideration of the neutral voltage and to study the effect of broken rotor bars on the different electrical quantities such as the park currents, torque, stator currents and neutral voltage. The performance of the model was assessed by comparing the simulation and experimental results. The obtained results show the effectiveness of the model, and allow detection and diagnosis of these defects.cs
dc.format.extent5647175 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoencs
dc.publisherVysoká škola báňská - Technická univerzita Ostravacs
dc.relation.ispartofseriesAdvances in electrical and electronic engineeringcs
dc.relation.urihttp://dx.doi.org/10.15598/aeee.v14i5.1705cs
dc.rights© Vysoká škola báňská - Technická univerzita Ostrava
dc.rightsCreative Commons Attribution 3.0 Unported (CC BY 3.0)
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectdiagnosticcs
dc.subjectneutral voltage signaturecs
dc.subjectpark currentscs
dc.subjectsquirrel cage induction machinecs
dc.subjectstator current signaturecs
dc.titleAdvanced model of squirrel cage induction machine for broken rotor bars fault using multi indicatorscs
dc.typearticlecs
dc.identifier.doi10.15598/aeee.v14i5.1705
dc.rights.accessopenAccess
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs


Files in this item

This item appears in the following Collection(s)

Show simple item record

© Vysoká škola báňská - Technická univerzita Ostrava
Except where otherwise noted, this item's license is described as © Vysoká škola báňská - Technická univerzita Ostrava