dc.description.abstract | Squirrel cage induction machine are the most commonly used electrical drives, but like any other machine, they are vulnerable to faults. Among the widespread failures of the induction machine there are rotor faults. This paper focuses on the detection of broken rotor bars fault using multi-indicator. However, diagnostics of asynchronous machine rotor faults can be accomplished by analysing the anomalies of machine local variable such as torque, magnetic flux, stator current and neutral voltage signature analysis. The aim of this research is to summarize the existing models and to develop new models of squirrel cage induction motors with consideration of the neutral voltage and to study the effect of broken rotor bars on the different electrical quantities such as the park currents, torque, stator currents and neutral voltage. The performance of the model was assessed by comparing the simulation and experimental results. The obtained results show the effectiveness of the model, and allow detection and diagnosis of these defects. | cs |
dc.format.extent | 5647175 bytes | |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | cs |
dc.publisher | Vysoká škola báňská - Technická univerzita Ostrava | cs |
dc.relation.ispartofseries | Advances in electrical and electronic engineering | cs |
dc.relation.uri | http://dx.doi.org/10.15598/aeee.v14i5.1705 | cs |
dc.rights | © Vysoká škola báňská - Technická univerzita Ostrava | |
dc.rights | Creative Commons Attribution 3.0 Unported (CC BY 3.0) | |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.subject | diagnostic | cs |
dc.subject | neutral voltage signature | cs |
dc.subject | park currents | cs |
dc.subject | squirrel cage induction machine | cs |
dc.subject | stator current signature | cs |
dc.title | Advanced model of squirrel cage induction machine for broken rotor bars fault using multi indicators | cs |