Zobrazit minimální záznam

dc.contributor.authorMartinek, Radek
dc.contributor.authorKahánková, Radana
dc.contributor.authorJeżewski, Janusz
dc.contributor.authorJaroš, René
dc.contributor.authorMohylová, Jitka
dc.contributor.authorFajkus, Marcel
dc.contributor.authorNedoma, Jan
dc.contributor.authorJanků, Petr
dc.contributor.authorNazeran, Homer
dc.date.accessioned2018-06-15T12:10:01Z
dc.date.available2018-06-15T12:10:01Z
dc.date.issued2018
dc.identifier.citationFrontiers in Physiology. 2018, vol. 9. art. no. 648.cs
dc.identifier.issn1664-042X
dc.identifier.urihttp://hdl.handle.net/10084/127298
dc.description.abstractNon-adaptive signal processing methods have been successfully applied to extract fetal electrocardiograms (fECGs) from maternal abdominal electrocardiograms (aECGs); and initial tests to evaluate the efficacy of these methods have been carried out by using synthetic data. Nevertheless, performance evaluation of such methods using real data is a much more challenging task and has neither been fully undertaken nor reported in the literature. Therefore, in this investigation, we aimed to compare the effectiveness of two popular non-adaptive methods (the ICA and PCA) to explore the non-invasive (NI) extraction (separation) of fECGs, also known as NI-fECGs from aECGs. The performance of these well-known methods was enhanced by an adaptive algorithm, compensating amplitude difference and time shift between the estimated components. We used real signals compiled in 12 recordings (real01-real12). Five of the recordings were from the publicly available database (PhysioNet-Abdominal and Direct Fetal Electrocardiogram Database), which included data recorded by multiple abdominal electrodes. Seven more recordings were acquired by measurements performed at the Institute of Medical Technology and Equipment, Zabrze, Poland. Therefore, in total we used 60 min of data (i.e., around 88,000 R waves) for our experiments. This dataset covers different gestational ages, fetal positions, fetal positions, maternal body mass indices (BMI), etc. Such a unique heterogeneous dataset of sufficient length combining continuous Fetal Scalp Electrode (FSE) acquired and abdominal ECG recordings allows for robust testing of the applied ICA and PCA methods. The performance of these signal separation methods was then comprehensively evaluated by comparing the fetal Heart Rate (fHR) values determined from the extracted fECGs with those calculated from the fECG signals recorded directly by means of a reference FSE. Additionally, we tested the possibility of non-invasive ST analysis (NI-STAN) by determining the T/QRS ratio. Our results demonstrated that even though these advanced signal processing methods are suitable for the non-invasive estimation and monitoring of the fHR information from maternal aECG signals, their utility for further morphological analysis of the extracted fECG signals remains questionable and warrants further work.cs
dc.format.extent16079298 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoencs
dc.publisherFrontiers Media S.A.cs
dc.relation.ispartofseriesFrontiers in Physiologycs
dc.relation.urihttps://doi.org/10.3389/fphys.2018.00648cs
dc.rights© 2018 Martinek, Kahankova, Jezewski, Jaros, Mohylova, Fajkus, Nedoma, Janku and Nazeran.cs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectelectronic fetal monitoring (EFM)cs
dc.subjectfetal electrocardiogram (fECG)cs
dc.subjectnon-invasive fetal heart rate (NI-fHR) estimationcs
dc.subjectnon-invasive fetal ECG (NI-fECG)cs
dc.subjectnonadaptive methodscs
dc.subjectindependent component analysis (ICA)cs
dc.subjectprincipal component analysis (PCA)cs
dc.subjectnon-invasive ST analysis (NI-STAN)cs
dc.titleComparative effectiveness of ICA and PCA in extraction of fetal ECG from abdominal signals: Toward non-invasive fetal monitoringcs
dc.typearticlecs
dc.identifier.doi10.3389/fphys.2018.00648
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs
dc.description.sourceWeb of Sciencecs
dc.description.volume9cs
dc.description.firstpageart. no. 648cs
dc.identifier.wos000433600400001


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© 2018 Martinek, Kahankova, Jezewski, Jaros, Mohylova, Fajkus, Nedoma, Janku and Nazeran.
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © 2018 Martinek, Kahankova, Jezewski, Jaros, Mohylova, Fajkus, Nedoma, Janku and Nazeran.