Zobrazit minimální záznam

dc.contributor.authorPatnaik, Samarjit
dc.contributor.authorNayak, Manas Ranjan
dc.contributor.authorViswavandya, Meera
dc.date.accessioned2023-04-14T09:24:33Z
dc.date.available2023-04-14T09:24:33Z
dc.date.issued2022
dc.identifier.citationAdvances in electrical and electronic engineering. 2022, vol. 20, no. 4, p. 523 - 536: ill.cs
dc.identifier.issn1336-1376
dc.identifier.issn1804-3119
dc.identifier.urihttp://hdl.handle.net/10084/149251
dc.description.abstractWind Turbine Generators (WTG) are being integrated into distribution systems on a large scale worldwide as part of a global effort to capture green energy. Wind turbine generator inter- mittency may be mitigated by Battery Energy Storage Systems (BESS), which have emerged as a viable option in recent years. To find the best position and capacity for wind power generation and BESS charging/discharging dispatches, a Red Fox Optimi- sation (RFO) algorithm is used while optimising the imbalanced distribution network’s performance under technological restrictions. The charging or discharging criteria for this method is the average feeder load. The charging techniques for BESS using WTG and Sustainable Average Load (SAL) are evaluated in terms of the free-running mode of dispatch cycle. The suggested approach is tested on an IEEE-37 bus Unbalanced Radial Distribution Network (UDN). It has been shown that the suggested method enhances several performance objectives of the distribution system.cs
dc.language.isoencs
dc.publisherVysoká škola báňská - Technická univerzita Ostravacs
dc.relation.ispartofseriesAdvances in electrical and electronic engineeringcs
dc.relation.urihttps://doi.org/10.15598/aeee.v20i4.4632cs
dc.rights© Vysoká škola báňská - Technická univerzita Ostrava
dc.rightsAttribution-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/4.0/*
dc.subjectwind turbine generatorcs
dc.subjectIEEE-37cs
dc.subjectbus unbalanced radial distribution networkcs
dc.subjectRed Fox Optimisation algorithmcs
dc.subjectSustainable Average Loadcs
dc.titleOptimal Battery Energy Storage System Management with Wind Turbine Generator in Unbalanced Low Power Distribution Systemcs
dc.typearticlecs
dc.identifier.doi10.15598/aeee.v20i4.4632
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© Vysoká škola báňská - Technická univerzita Ostrava
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © Vysoká škola báňská - Technická univerzita Ostrava