dc.identifier.citationAdvances in electrical and electronic engineering. 2023, vol. 21, no. 2, p. 67 - 80 : ill.cs
dc.identifier.issn1336-1376
dc.identifier.issn1804-3119
dc.identifier.urihttp://hdl.handle.net/10084/151442
dc.description.abstractThe purpose of this work is to develop proposals for modernizing the design of turbogener- ators with a capacity of 200–300 MW in order to increase their power. To increase the power, it is pro- posed to increase the generator electromagnetic param- eters (induction in the magnetic circuit and linear load of the generator). At the same time, the possibility of replacing hydrogen, which cools the generator internal volume, on the air was studied, which is a global trend for turbogenerators of thermal power plants with a ca- pacity of 200–300 MW. A prerequisite was the preser- vation of the turbogenerator dimensions. The set goals were achieved by changing the geometry of the stator core tooth zone and intensifying cooling. To determine the necessary changes in the tooth zone with a change in the electromagnetic and thermal characteristics of the turbogenerator, a mathematical model was devel- oped that makes it possible to determine by calculation the required dimensions and configuration of the stator slots and gas cooler elements at condition that the per- missible thermal characteristics are maintained. The modelling of the stator core was carried out in order to select the dimensions of the slots and channels of axial ventilation for the required mode of the coolers operation, subject to an increase in power.cs
dc.language.isoencs
dc.publisherVysoká škola báňská - Technická univerzita Ostravacs
dc.relation.ispartofseriesAdvances in electrical and electronic engineeringcs
dc.relation.urihttps://doi.org/10.15598/aeee.v21i2.4471cs
dc.rights© Vysoká škola báňská - Technická univerzita Ostrava
dc.rightsAttribution-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/4.0/*
dc.subjectpower increasecs
dc.subjectthermal power plantcs
dc.subjecttooth zone of the stator corecs
dc.subjectturbogenerator coolingcs
dc.subjectturbogenerator modernizationcs
dc.titleProposals for the Modernization of TPP Turbogeneratorscs
dc.typearticlecs
dc.identifier.doi10.15598/aeee.v21i2.4471
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© Vysoká škola báňská - Technická univerzita Ostrava
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © Vysoká škola báňská - Technická univerzita Ostrava