dc.description.abstract | The purpose of this work is to develop
proposals for modernizing the design of turbogener-
ators with a capacity of 200–300 MW in order to
increase their power. To increase the power, it is pro-
posed to increase the generator electromagnetic param-
eters (induction in the magnetic circuit and linear load
of the generator). At the same time, the possibility of
replacing hydrogen, which cools the generator internal
volume, on the air was studied, which is a global trend
for turbogenerators of thermal power plants with a ca-
pacity of 200–300 MW. A prerequisite was the preser-
vation of the turbogenerator dimensions. The set goals
were achieved by changing the geometry of the stator
core tooth zone and intensifying cooling. To determine
the necessary changes in the tooth zone with a change
in the electromagnetic and thermal characteristics of
the turbogenerator, a mathematical model was devel-
oped that makes it possible to determine by calculation
the required dimensions and configuration of the stator
slots and gas cooler elements at condition that the per-
missible thermal characteristics are maintained. The
modelling of the stator core was carried out in order
to select the dimensions of the slots and channels of
axial ventilation for the required mode of the coolers
operation, subject to an increase in power. | cs |
dc.language.iso | en | cs |
dc.publisher | Vysoká škola báňská - Technická univerzita Ostrava | cs |
dc.relation.ispartofseries | Advances in electrical and electronic engineering | cs |
dc.relation.uri | https://doi.org/10.15598/aeee.v21i2.4471 | cs |
dc.rights | © Vysoká škola báňská - Technická univerzita Ostrava | |
dc.rights | Attribution-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nd/4.0/ | * |
dc.subject | power increase | cs |
dc.subject | thermal power plant | cs |
dc.subject | tooth zone of the stator core | cs |
dc.subject | turbogenerator cooling | cs |
dc.subject | turbogenerator modernization | cs |
dc.title | Proposals for the Modernization of TPP Turbogenerators | cs |
dc.type | article | cs |
dc.identifier.doi | 10.15598/aeee.v21i2.4471 | |
dc.rights.access | openAccess | cs |
dc.type.version | publishedVersion | cs |
dc.type.status | Peer-reviewed | cs |