dc.contributor.author | Lysiak, Vladyslav | |
dc.date.accessioned | 2023-10-24T11:31:53Z | |
dc.date.available | 2023-10-24T11:31:53Z | |
dc.date.issued | 2023 | |
dc.identifier.citation | Advances in electrical and electronic engineering. 2023, vol. 21, no. 3, p. 226-234 : ill. | cs |
dc.identifier.issn | 1336-1376 | |
dc.identifier.issn | 1804-3119 | |
dc.identifier.uri | http://hdl.handle.net/10084/151463 | |
dc.description.abstract | Based on the system approach and the
principle of electrohydrodynamic analogy, a formal-
ized mathematical model of a generalized system of
asynchronous centrifugal pumping units of a multi-unit
pumping station with an asynchronous electric drive of
centrifugal pumps was created. This model is easy to
adapt to the specific configuration of the pumping sta-
tion. A feature of the model is the use of such pa-
rameters of the centrifugal pump, which are calculated
directly through the geometric dimensions of its inter-
nal elements, taking into account the dependence of
these parameters on the physical properties of the work-
ing fluid. Unlike existing models, this makes it pos-
sible to take into account the influence of operational
or emergency changes in pump parameters and opera-
tional changes in the physical properties of the working
fluid both on its pumping regimes and on the operation
regimes of the electric drive directly during the simu-
lation. The scope of use and ways of improving the
developed model, as well as the direction of further re-
search, are proposed. | cs |
dc.language.iso | en | cs |
dc.publisher | Vysoká škola báňská - Technická univerzita Ostrava | cs |
dc.relation.ispartofseries | Advances in electrical and electronic engineering | cs |
dc.relation.uri | https://doi.org/10.15598/aeee.v21i3.4718 | cs |
dc.rights | © Vysoká škola báňská - Technická univerzita Ostrava | |
dc.rights | Attribution-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nd/4.0/ | * |
dc.subject | induction machine | cs |
dc.subject | centrifugal pump | cs |
dc.subject | model | cs |
dc.subject | pipeline | cs |
dc.subject | pumping station | cs |
dc.title | Mathematical Modeling Of Multi-Units Pumping Station With Asynchronous Electric Drive Of Centrifugal Pumps | cs |
dc.type | article | cs |
dc.identifier.doi | 10.15598/aeee.v21i3.4718 | |
dc.rights.access | openAccess | cs |
dc.type.version | publishedVersion | cs |
dc.type.status | Peer-reviewed | cs |