dc.description.abstractWith the increasing adoption of solar Pho- tovoltaic (PV) systems in several applications, reliabil- ity and service continuity are important challenges that need to be addressed. Power converters are vital com- ponents in solar PV systems and inverters tend to be the most likely devices of equipment to experience faults which usually occur in the switching devices. It is there- fore critical to assess the functioning of the inverters and identify these faults in order to lower risks and the resulting financial losses. Open-circuit faults (OCF) are among the most common. This paper suggests a fuzzy-based fault detection approach for the T-Type in- verter in grid connected PV system based on the diag- nosis variables which are calculated using the average values of positive and the negative parts of the normal- ized output currents data. After that, these variables are analyzed using a fuzzy logic technique, The single, multiple power switch open circuit faults may all be de- tected and diagnosed utilizing this fuzzy-based fault di- agnostic technique. The results of the simulation in MATLAB show that the proposed method can accu- rately identify and locate OCF the inverter switches.cs
dc.language.isoencs
dc.publisherVysoká škola báňská - Technická univerzita Ostravacs
dc.relation.ispartofseriesAdvances in electrical and electronic engineeringcs
dc.relation.urihttps://doi.org/10.15598/aeee.v21i4.5218cs
dc.rights© Vysoká škola báňská - Technická univerzita Ostrava
dc.rightsAttribution-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/4.0/*
dc.subjectgrid connected PV systemcs
dc.subjectT-Type invertercs
dc.subjectfault diagnosiscs
dc.subjectOpen circuit fault (OCF)cs
dc.subjectfuzzy logic approachcs
dc.titleIdentification of Open-Circuit Faults in T-Type Inverters Using Fuzzy Logic Approachcs
dc.typearticlecs
dc.identifier.doi10.15598/aeee.v21i4.5218
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© Vysoká škola báňská - Technická univerzita Ostrava
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © Vysoká škola báňská - Technická univerzita Ostrava