Zobrazit minimální záznam

dc.contributor.authorFranklin, J.
dc.contributor.authorPongiannan, R.K.
dc.contributor.authorNarayanamoorthi, R.
dc.date.accessioned2024-10-22T12:25:05Z
dc.date.available2024-10-22T12:25:05Z
dc.date.issued2024
dc.identifier.citationAdvances in electrical and electronic engineering. 2024, vol. 22, no. 3, p. 297-307 : ill.cs
dc.identifier.issn1336-1376
dc.identifier.issn1804-3119
dc.identifier.urihttp://hdl.handle.net/10084/155197
dc.description.abstractThe effectiveness of a Voltage Source Inverter (VSI) operating in a single-phase configuration controlled using Pulse Width Modulation (PWM) depends on multiple factors, particularly a special attention given to the Delay Time (DT) linked to the switching of power devices within the same arm. The ramifications of DT in a single-phase VSI have notable effects on output quality, harmonic content, and transient responsiveness. In this paper, a DT compensator is implemented for a single-phase VSI using the Average Based Pulse Compensation (ABPC) method. This technique adjusts switching instant to counteract the effects of DT and mitigate voltage distortions, reduce harmonic content, and enhance waveform quality. Simulations and validations are performed using MATLAB/Simulink to evaluate compensator performance under different operating conditions. The compensator design is implemented in hardware through the utilization of an FPGA SPARTAN 6 XC6SLX9 controller, tasked with generating a PWM pulse. The quality of ouput voltage and current has been improved by ABP compensation and the THD is reduced by 20%. Additionally, a laboratory testing phase is conducted to assess the performance of the proposed method, involving the validation of a prototype for a single-phase PWM inverter.cs
dc.language.isoencs
dc.publisherVysoká škola báňská - Technická univerzita Ostravacs
dc.relation.ispartofseriesAdvances in electrical and electronic engineeringcs
dc.relation.urihttps://doi.org/10.15598/aeee.v22i3.5754cs
dc.rights© Vysoká škola báňská - Technická univerzita Ostrava
dc.rightsAttribution-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/4.0/*
dc.subjectdelay time (DT)cs
dc.subjectsingle-phase VSIcs
dc.subjectaverage based pulse compensation (ABPC) methodcs
dc.subjecttotal harmonic distortion (THD)cs
dc.subjectfield-programmable gate array (FPGA)cs
dc.titlePerformance Enhancing of Single-Phase Voltage Source Inverter Through Average-Based Pulse Delay Time Compensationcs
dc.typearticlecs
dc.identifier.doi10.15598/aeee.v22i3.5754
dc.rights.accessopenAccesscs
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

© Vysoká škola báňská - Technická univerzita Ostrava
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je © Vysoká škola báňská - Technická univerzita Ostrava