dc.contributor.author | Hanusová, Naděžda | |
dc.contributor.author | Zahradník, Jiří | |
dc.date.accessioned | 2011-02-01T11:34:18Z | |
dc.date.available | 2011-02-01T11:34:18Z | |
dc.date.issued | 2006 | |
dc.identifier.citation | Advances in electrical and electronic engineering. 2006, vol. 5, no. 3, p. 132-135. | en |
dc.identifier.issn | 1336-1376 | |
dc.identifier.uri | http://hdl.handle.net/10084/83784 | |
dc.description.abstract | The article deals with methodology of a system failure rate calculation that is based on the adoption of the
condition l.t<<1. Assuming that the condition is satisfied, the serial-parallel system failure rate calculation is easier and the
results are either the same or worse from a view of system reliability evaluation. So the results can be accepted. A simple
example will be given as a confirmation of the assertion. | en |
dc.format.extent | 139832 bytes | cs |
dc.format.mimetype | application/pdf | cs |
dc.language.iso | en | en |
dc.publisher | Žilinská univerzita v Žiline. Elektrotechnická fakulta | en |
dc.relation.ispartofseries | Advances in electrical and electronic engineering | en |
dc.relation.uri | http://advances.utc.sk/index.php/AEEE | en |
dc.rights | Creative Commons Attribution 3.0 Unported (CC BY 3.0) | en |
dc.rights | © Žilinská univerzita v Žiline. Elektrotechnická fakulta | en |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | en |
dc.title | System failure rate calculation | en |
dc.type | article | en |
dc.rights.access | openAccess | |
dc.type.version | publishedVersion | cs |
dc.type.status | Peer-reviewed | cs |