Zobrazit minimální záznam

dc.contributor.authorBaranová, L.
dc.contributor.authorZáliš, Karel
dc.date.accessioned2011-02-07T08:44:22Z
dc.date.available2011-02-07T08:44:22Z
dc.date.issued2008
dc.identifier.citationAdvances in electrical and electronic engineering. 2008, vol. 7, no. 1, 2, p. 125-127.en
dc.identifier.issn1336-1376
dc.identifier.urihttp://hdl.handle.net/10084/84015
dc.description.abstractDiagnostics by partial discharge measurement is a modern diagnostic method for determination of the state of insulating systems of high voltage machines and equipment. In the High Voltage Laboratory of the Czech Technical University in Prague was developed the complex measuring and evaluating system for partial discharge measurement. Unfortunately, the main problem of discharge activity measurement in practice is in electromagnetic disturbance. This article is focused on the removing this disturbance from measured data. Great problems in the evaluation of partial discharge data is in various sorts of interferences. The most of disturbing signals was eliminated by using of a suitable circuit modification, but others could be only convert (in the case of partial discharge signals into digital form) by using suitable computing programs for the processing and saving of measured data. In this article two basic algorithms are described for the elimination of main disturbing signals from digitized partial discharge data. At first, the algorithms for the elimination randomize disturbing signals and the second, for the SCR disturbing (from thyristors). Two math theorems were applied to all measured samples by the computing program. In another way for the elimination of disturbances from partial data is the mathematical Wavelet analysis, which makes possible the elimination of more types of disturbance.en
dc.format.extent126534 bytescs
dc.format.mimetypeapplication/pdfcs
dc.language.isoenen
dc.publisherŽilinská univerzita v Žiline. Elektrotechnická fakultaen
dc.relation.ispartofseriesAdvances in electrical and electronic engineeringen
dc.relation.urihttp://advances.utc.sk/index.php/AEEEen
dc.rightsCreative Commons Attribution 3.0 Unported (CC BY 3.0)
dc.rights© Žilinská univerzita v Žiline. Elektrotechnická fakulta
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/
dc.titlePartial discharge measurement in operation: problems with disturbances and their removingen
dc.typearticleen
dc.rights.accessopenAccess
dc.type.versionpublishedVersioncs
dc.type.statusPeer-reviewedcs


Soubory tohoto záznamu

Tento záznam se objevuje v následujících kolekcích

  • AEEE. 2008, vol. 7 [106]
  • OpenAIRE [5085]
    Kolekce určená pro sklízení infrastrukturou OpenAIRE; obsahuje otevřeně přístupné publikace, případně další publikace, které jsou výsledkem projektů rámcových programů Evropské komise (7. RP, H2020, Horizon Europe).

Zobrazit minimální záznam

Creative Commons Attribution 3.0 Unported (CC BY 3.0)
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 3.0 Unported (CC BY 3.0)