dc.contributor.author | Krasl, Milan | |
dc.contributor.author | Pechánek, R. | |
dc.contributor.author | Vlk, R. | |
dc.date.accessioned | 2011-02-07T09:37:16Z | |
dc.date.available | 2011-02-07T09:37:16Z | |
dc.date.issued | 2008 | |
dc.identifier.citation | Advances in electrical and electronic engineering. 2008, vol. 7, no. 1, 2, p. 191-194. | en |
dc.identifier.issn | 1336-1376 | |
dc.identifier.uri | http://hdl.handle.net/10084/84143 | |
dc.description.abstract | This paper deals with comparing 3 types of transformers - superconducting, oil-immersed and middle-frequency.
These transformers can be used for locomotive as the main transformer. Weight, sizes and losses are introduced. The
influence of eddy currents is describes by middle-frequency transformer. The article deals with magnetic properties of
materials for higher frequency. | en |
dc.format.extent | 721675 bytes | cs |
dc.format.mimetype | application/pdf | cs |
dc.language.iso | en | en |
dc.publisher | Žilinská univerzita v Žiline. Elektrotechnická fakulta | en |
dc.relation.ispartofseries | Advances in electrical and electronic engineering | en |
dc.relation.uri | http://advances.utc.sk/index.php/AEEE | en |
dc.rights | Creative Commons Attribution 3.0 Unported (CC BY 3.0) | |
dc.rights | © Žilinská univerzita v Žiline. Elektrotechnická fakulta | |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | |
dc.title | Traction transformer 1 MV.A, superconducting, oil-immersed and medium frequency | en |
dc.type | article | en |
dc.rights.access | openAccess | |
dc.type.version | publishedVersion | cs |
dc.type.status | Peer-reviewed | cs |