POF-based biosensors for cortisol detection in seawater as a tool for aquaculture systems

dc.contributor.authorArcadio, Francesco
dc.contributor.authorSoares, Simone
dc.contributor.authorNedoma, Jan
dc.contributor.authorAguiar, Dayana
dc.contributor.authorPereira, Ana Cristina
dc.contributor.authorZeni, Luigi
dc.contributor.authorCennamo, Nunzio
dc.contributor.authorMarques, Carlos
dc.date.accessioned2026-05-07T14:33:39Z
dc.date.available2026-05-07T14:33:39Z
dc.date.issued2024
dc.description.abstractA surface plasmon resonance (SPR) phenomenon implemented via D-shaped polymer optical fiber (POF) is exploited to realize cortisol biosensors. In this work, two immonosensors are designed and developed for the qualitative as well as quantitative measurement of cortisol in artificial and real samples. The performances of the POF-based biosensors in cortisol recognition are achieved using different functionalization protocols to make the same antibody receptor layer over the SPR surface via cysteamine and lipoic acid, achieving a limit of detection (LOD) of 0.8 pg/mL and 0.2 pg/mL, respectively. More specifically, the use of cysteamine or lipoic acid changes the distance between the receptor layer and the SPR surface, improving the sensitivity at low concentrations of about one order of magnitude in the configuration based on lipoic acid. The LODs of both cortisol biosensors are achieved well competitively with other sensor systems but without the need for amplification or sample treatments. In order to obtain the selectivity tests, cholesterol and testosterone were used as interfering substances. Moreover, tests in simulated seawater were performed for the same cortisol concentration range achieved in buffer solution to assess the immunosensor response to the complex matrix. Finally, the developed cortisol biosensor was used in a real seawater sample to estimate the cortisol concentration value. The gold standard method has confirmed the estimated cortisol concentration value in real seawater samples. Liquid-liquid extraction was implemented to maximize the response of cortisol in liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) analysis.
dc.description.firstpageart. no. 13117
dc.description.issue1
dc.description.sourceWeb of Science
dc.description.volume14
dc.identifier.citationScientific Reports. 2024, vol. 14, issue 1, art. no. 13117.
dc.identifier.doi10.1038/s41598-024-63870-7
dc.identifier.urihttp://hdl.handle.net/10084/158576
dc.identifier.wos001244401200002
dc.language.isoen
dc.publisherSpringer Nature
dc.relation.ispartofseriesScientific Reports
dc.relation.urihttps://doi.org/10.1038/s41598-024-63870-7
dc.rightsCopyright © 2024, The Author(s)
dc.rights.accessopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titlePOF-based biosensors for cortisol detection in seawater as a tool for aquaculture systems
dc.typearticle
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion
local.files.count1
local.files.size1898806
local.has.filesyes

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
2045-2322-2024v14i1an13117.pdf
Size:
1.81 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: