Surface plasmon resonance-based sensing utilizing spatial phase modulation in an imaging interferometer

dc.contributor.authorKaňok, Roman
dc.contributor.authorCiprian, Dalibor
dc.contributor.authorHlubina, Petr
dc.date.accessioned2021-03-01T11:19:19Z
dc.date.available2021-03-01T11:19:19Z
dc.date.issued2020
dc.description.abstractSpatial phase modulation in an imaging interferometer is utilized in surface plasmon resonance (SPR) based sensing of liquid analytes. In the interferometer, a collimated light beam from a laser diode irradiating at 637.1 nm is passing through a polarizer and is reflected from a plasmonic structure of SF10/Cr/Au attached to a prism in the Kretschmann configuration. The beam passes through a combination of a Wollaston prism, a polarizer and a lens, and forms an interference pattern on a CCD sensor of a color camera. Interference patterns obtained for different liquid analytes are acquired and transferred to the computer for data processing. The sensing concept is based on the detection of a refractive index change, which is transformed via the SPR phenomenon into an interference fringe phase shift. By calculating the phase shift for the plasmonic structure of SF10/Cr/Au of known parameters we demonstrate that this technique can detect different weight concentrations of ethanol diluted in water, or equivalently, different changes in the refractive index. The sensitivity to the refractive index and the detection limit obtained are 278 rad/refractive-index-unit (RIU) and 3.6 x 10(-6) RIU, respectively. The technique is demonstrated in experiments with the same liquid analytes as in the theory. Applying an original approach in retrieving the fringe phase shift, we revealed good agreement between experiment and theory, and the measured sensitivity to the refractive index and the detection limit reached 226 rad/RIU and 4.4 x 10(-6) RIU, respectively. These results suggest that the SPR interferometer with the detection of a fringe phase shift is particularly useful in applications that require measuring refractive index changes with high sensitivity.cs
dc.description.firstpageart. no. 1616cs
dc.description.issue6cs
dc.description.sourceWeb of Sciencecs
dc.description.volume20cs
dc.identifier.citationSensors. 2020, vol. 20, issue 6, art. no. 1616.cs
dc.identifier.doi10.3390/s20061616
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10084/142900
dc.identifier.wos000529139700075
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesSensorscs
dc.relation.urihttp://doi.org/10.3390/s20061616cs
dc.rights© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectsurface plasmon resonancecs
dc.subjectKretschmann configurationcs
dc.subjectspatial phase modulationcs
dc.subjectimaging interferometercs
dc.subjectfringe phase shiftcs
dc.subjectsensitivitycs
dc.subjectaqueous solutions of ethanolcs
dc.titleSurface plasmon resonance-based sensing utilizing spatial phase modulation in an imaging interferometercs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
1424-8220-2020v20i6an1616.pdf
Size:
1.49 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: