Error analysis of narrowband power-line communication in the off-grid electrical system

dc.contributor.authorBlažek, Vojtěch
dc.contributor.authorSlanina, Zdeněk
dc.contributor.authorPetružela, Michal
dc.contributor.authorHrbáč, Roman
dc.contributor.authorVysocký, Jan
dc.contributor.authorProkop, Lukáš
dc.contributor.authorMišák, Stanislav
dc.contributor.authorWalendziuk, Wojciech
dc.date.accessioned2022-06-21T08:17:06Z
dc.date.available2022-06-21T08:17:06Z
dc.date.issued2022
dc.description.abstractNarrowband power-line communication seems to be a suitable communication technology designed for off-grid renewable energy solutions. Existing electrical installations can be designed both for the transmission of electricity and for the communication of electrical equipment operating inside such an installation. This study presents an implementation of the above-mentioned off-grid communication system and examines the basic problems related to its exploitation. The authors of this article focused their attention primarily on examining the disturbance of the communication channel caused by the use of typical electrical devices, such as: a light bulb, a kettle, etc. used in a household. The aim of the research was also to find the impact of switching on individual devices and their combinations on the disturbances during data transmission. Measurements of incorrectly transmitted data packets were carried out and then the test results were referred to the error measures. Moreover, the influence of the carrier frequencies on the signal attenuation and the method of eliminating the existing interferences were also discussed.cs
dc.description.firstpageart. no. 2265cs
dc.description.issue6cs
dc.description.sourceWeb of Sciencecs
dc.description.volume22cs
dc.identifier.citationSensors. 2022, vol. 22, issue 6, art. no. 2265.cs
dc.identifier.doi10.3390/s22062265
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10084/146297
dc.identifier.wos000774607500001
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesSensorscs
dc.relation.urihttps://doi.org/10.3390/s22062265cs
dc.rights© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectpower line communicationcs
dc.subjectoff-gridcs
dc.subjectmicrogridcs
dc.titleError analysis of narrowband power-line communication in the off-grid electrical systemcs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
1424-8220-2022v22i6an2265.pdf
Size:
4.1 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: